Electrolux KSV26HRC Service Manual page 88

Kelvinator inverter split system
Hide thumbs Also See for KSV26HRC:
Table of Contents

Advertisement

Diagnostic Display Mode Description:
Built into the software for models: KSV62, 70 & 80HRC are two different diagnostic methods:
(Fault Codes & Condition Codes) that can be used to help diagnose various faults.
These two diagnostic types are described in the following pages.
Note: Where there is referral to (Delayed)
# This indicates a time delay before the fault code in question is displayed.
Note: Where there is a referral to (Remote Control Access – 4)
# This indicates the need to use the remote controller to view the relevant fault code.
This is achieved by pressing the "Light" button 4 times within three seconds.
Note: Where there is a referral to (Remote Control Access – 5)
# This indicates the need to use the remote controller to initiate a selected "Test State".
This is achieved by pressing the "Light" button 5 times within three seconds.
Note: Where there is a referral to (DRED)
# This indicates the unit in question is fitted with a "Demand Response Electrical Device" that
enables the compressor to operate at various capacities (75% of total capacity, 50% of total
capacity & compressor off).
Note: The DRED device is provided & controlled by the local electrical authorities help control
peak demand periods.
Fault Code Descriptions:
E4, Indoor Unit. (Compressor Discharge High Temperature Protection)
Indoor Standby LED, flash 4 times. {Delayed}
Yellow-D5 LED, Outdoor unit On.
Orange-D6 LED, Outdoor unit. Off.
Green-D16 LED, Outdoor unit On.
Red-D30 LED, Outdoor unit Flashing.
# Check the outdoor coil for airflow obstructions.
# Check the outdoor fan motor for correct operation.
E5, Indoor Unit. (AC Over-Current Protection)
Indoor Standby LED, flash 5 times.
Yellow-D5 LED, Outdoor unit Off.
Orange-D6 LED, Outdoor unit. On.
Green-D16 LED, Outdoor unit Flashing.
Red-D30 LED, Outdoor unit Off.
# While the unit is in operation, check the maximum current draw. If it's above the maximum
current rating illustrated on the outdoor rating plate, check operation of the compressor.