Fan mode, cooling mode:
In auto cooling mode or normal cooling mode, auto fan speed operates according to below mode:
When (indoor ambient temperature - Tamb.) is 3ºC or more above (indoor preset temperature – Tpreset.), indoor fan
operates at high speed.
When (indoor ambient temperature - Tamb.) is 2 to 3ºC above (indoor preset temperature – Tpreset.), indoor fan
operates at medium speed.
When (indoor ambient temperature - Tamb.) is 1 to 2ºC above (indoor preset temperature – Tpreset.), indoor fan
operates at low speed.
When (indoor ambient temperature - Tamb.) is the same or 1ºC above (indoor preset temperature – Tpreset.), indoor fan
operates at quiet mode.
Page 52 KSSSI116