Condition Code Continues:
EU, Indoor Unit. (IPM Over Temperature Limit)
Indoor Heating LED, flash 6 times. {Remote Control Access - 4}
Indoor Cooling LED, flash 6 times.
Yellow-D5 LED, Outdoor unit On.
Orange-D6 LED, Outdoor unit On.
Green-D16 LED, Outdoor unit On.
Red-D30 LED, Outdoor unit Flashing.
# Check the outdoor coil for airflow obstructions.
# Check operation of outdoor fan motor.
F6, Indoor Unit. (Anti-High Temperature Protection)
Indoor Cooling LED, flash 6 times. {Remote Control Access - 4}
Yellow-D5 LED, Outdoor unit On.
Orange-D6 LED, Outdoor unit Off.
Green-D16 LED, Outdoor unit Flashing.
Red-D30 LED, Outdoor unit Flashing.
# Check the outdoor coil for airflow obstructions.
# Check the outdoor fan motor for correct operation.
PO, Indoor Unit. {Remote Control Access - 5}
(Compressor Minimum Frequency - Test State)
# Set remote control in Cooling mode: 16ºC or Heating mode: 27ºC.
P1, Indoor Unit. {Remote Control Access - 5}
(Compressor Rated Frequency - Test State)
# Set remote control in Cooling mode: 18ºC or Heating mode: 29ºC.
P2, Indoor Unit. {Remote Control Access - 5}
(Compressor Maximum Frequency - Test State)
# Set remote control in Cooling mode: 19ºC or Heating mode: 30ºC.
P3, Indoor Unit. {Remote Control Access - 5}
(Compressor Medium Frequency - Test State)
# Set remote control to Cooling mode: 17ºC or Heating mode: 28ºC.