Electrical Work; Installation Of Indoor And Outdoor Electric Wires - Electrolux KSV26HRC Service Manual

Kelvinator inverter split system
Hide thumbs Also See for KSV26HRC:
Table of Contents

Advertisement

Electrical Work:

CAPACITY
KSV26HRC
KSV35HRC
KSV26CRC
KSV35CRC
CAPACITY
KSV53HRC
KSV62HRC
KSV70CRC
KSV70HRC
KSV80HRC

Installation of indoor and outdoor electric wires:

1. Open the front panel.
2. Remove the wiring cover.
3. Connect and fix the power connection cord to the terminal block.
4. Make the power connection cord pass through the hole at the back of indoor unit.
5. Reinstall the cord anchorage and wiring cover.
6. Reinstall the front panel.
Note:
All wires between indoor and outdoor units must be connected by a qualified electric contractor.
• Electric wires must be connected correctly. Improper connection may cause malfunction.
• Tighten the terminal screws tightly.
• After tightening the screws, pull the wire slightly to confirm whether it's anchored correctly.
• Make sure that the electric connections are earthed properly to prevent electric shock.
• Make sure that all wiring connections are secure and the cover plates are reinstalled properly. Poor installation may
cause fire or electric shock.
Page 39 KSSSI116
POWER SUPPLY
220-240V~/50Hz
POWER SUPPLY
220-240V~/50Hz
INPUT RATED AMP
Switch/Fuse
16A/16A
INPUT RATED AMP
Switch/Fuse
25A
CABLE SIZE
2
1.0 mm
(power cord)
2
1.0 mm
(connecting cable)
CABLE SIZE
2
2.5 mm
(power cord)
2
2.5 mm
(connecting cable)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ksv35hrcKsv70hrcKsv53hrcKsv80hrcKsv62hrc