Dry Mode:

Drying Conditions and Process (KSV26 & 35CRC/HRC)
When (indoor ambient temperature - Tamb.) is above (indoor preset temperature - Tpreset), the unit operates in
cooling mode, with the compressor and outdoor fan in operation. Indoor fan operates at set fan speed (low fan speed,
quiet fan speed).
When (indoor ambient temperature - Tamb.) is -2ºC below (indoor preset temperature - Tpreset), compressor, outdoor
fan and indoor fan operate at set fan speed (low fan speed, quiet fan speed).
Under this mode, the temperature setting range is 16~30℃. Display displays operation icon, drying icon and set
temperature.