Model & PNC (Outdoor Unit)
Compressor Manufacturer/Trademark
Compressor Model
Compressor Oil
Compressor Type
L.R.A.
Compressor RLA
Compressor Power Input
Overload Protector
Throttling Method
Operation temp
Ambient temp (cooling)
Ambient temp (heating)
Condenser Form
Pipe Diameter
Rows-fin Gap
Coil Length (LXDXW)
Fan Motor Speed
Output of Fan Motor
Air Flow Volume of Outdoor Unit
Fan Type
Fan Diameter
Defrosting Method
Climate Type
Isolation
Moisture Protection
Permissible Excessive Operating Pressure for the
Discharge Side
Permissible Excessive Operating Pressure for the
Suction Side
Sound Pressure Level (Maximum)
Sound Power Level (Maximum)
Dimension (WXHXD)
Dimension of Carton Box (L/W/H)
Dimension of Package (L/W/H)
Net Weight
Gross Weight
Refrigerant
Refrigerant Charge
Length (Standard)
Gas Additional Charge (>7.5M)
Outer Diameter Liquid Pipe
Outer Diameter Gas Pipe
Max Distance Height
Max Distance Length
KSV62HRC/950132913
MITSUBISHI/MITSUBISHI ELECTRIC
(GUANGZHOU)COMP
A
A
W
Aluminium Fin-copper Tube
mm
mm
mm
rpm
W
3
m
/h
mm
MPa
MPa
dB
(A)
dB
(A)
mm
mm
mm
kg
kg
kg
m
g/m
mm
mm
m
m
SNB130FGYMC-L1
FV50S
Rotary
27.00
8.40
1245
1NT11L-6578
Capillary
16 / 30
10 / 48
-15 / 24
Φ7
3-1.4
823.5X38.1X649
700
60
3200
Axial-flow
Φ520
Automatic Defrosting
T1
I
IP24
4.3
2.5
56
66
955X700X396
1026X455X735
1029X458X750
50
54
R410A
1.90
7.5
50
Φ6.35
Φ16
10
25