B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 26 of 57)
ADDR
REGISTER NAME
65CC
Power Swing Detect Delay 1 Reset
65CD
Power Swing Detect Delay 2 Pickup
65CE
Power Swing Detect Delay 3 Pickup
65CF
Power Swing Detect Delay 4 Pickup
65D0
Power Swing Detect Seal In Delay
B
65D1
Power Swing Detect Trip Mode
65D2
Power Swing Detect Block
65D3
Power Swing Detect Target
65D4
Power Swing Detect Event
65D5
Power Swing Detect Shape
65D6
Power Swing Detect Quad Forward Middle
65D7
Power Swing Detect Quad Forward Outer
65D8
Power Swing Detect Quad Reverse Middle
65D9
Power Swing Detect Quad Reverse Outer
65DA
Power Swing Detect Outer Right Blinder
65DB
Power Swing Detect Outer Left Blinder
65DC
Power Swing Detect Middle Right Blinder
65DD
Power Swing Detect Middle Left Blinder
65DE
Power Swing Detect Inner Right Blinder
65DF
Power Swing Detect Inner Left Blinder
Load Encroachment (Read/Write Grouped Setting)
6700
Load Encroachment Function
6701
Load Encroachment Source
6702
Load Encroachment Minimum Voltage
6703
Load Encroachment Reach
6704
Load Encroachment Angle
6705
Load Encroachment Pickup Delay
6706
Load Encroachment Reset Delay
6707
Load Encroachment Block
6708
Load Encroachment Target
6709
Load Encroachment Events
670A
Reserved (6 items)
Trip Output (Read/Write Setting)
67E0
Trip Mode
67E1
Trip 3-Pole Input1
67E2
Trip 3-Pole Input2
67E3
Trip 3-Pole Input3
67E4
Trip 3-Pole Input4
67E5
Trip 3-Pole Input5
67E6
Trip 3-Pole Input6
67E7
Trip 1-Pole Input1
67E8
Trip 1-Pole Input2
67E9
Trip 1-Pole Input3
67EA
Trip 1-Pole Input4
67EB
Trip 1-Pole Input5
67EC
Trip 1-Pole Input6
67ED
Trip Reclose Input1
67EE
Trip Reclose Input2
67EF
Trip Reclose Input3
67F0
Trip Reclose Input4
67F1
Trip Reclose Input5
67F2
Trip Reclose Input6
67F3
Trip Force 3-Pole
67F4
Trip Pilot Priority
B-34
RANGE
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 1
0 to 65535
0 to 2
0 to 1
0 to 1
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0 to 1
0 to 5
0 to 3
0.02 to 250
5 to 50
0 to 65.535
0 to 65.535
0 to 65535
0 to 2
0 to 1
0 to 65535
0 to 2
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65.535
L90 Line Current Differential System
UNITS
STEP
FORMAT
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F514
---
1
F300
---
1
F109
---
1
F102
---
1
F085
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
---
1
F102
---
1
F167
pu
0.001
F001
ohms
0.01
F001
degrees
1
F001
s
0.001
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F195
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
APPENDIX B
DEFAULT
50
17
9
17
400
0 (Delayed)
0
0 (Self-reset)
0 (Disabled)
0 (Mho Shape)
6000
7000
6000
7000
10000
10000
10000
10000
10000
10000
0 (Disabled)
0 (SRC 1)
250
100
30
0
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
GE Multilin