B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 24 of 57)
ADDR
REGISTER NAME
Setting Groups (Read Only)
5F8B
Current Setting Group
Setting Group Names (Read/Write Setting)
5F8C
Setting Group 1 Name
5F94
Setting Group 2 Name
B
5F9C
Setting Group 3 Name
5FA4
Setting Group 4 Name
5FAC
Setting Group 5 Name
5FB4
Setting Group 6 Name
Current Differential 87L (Read/Write Grouped Setting)
6000
87L Current Differential Function
6001
87L Current Differential Block
6002
87L Current Differential Signal Source 1
6003
87L Minimum Phase Current Sensitivity
6004
87L Current Differential Tap Setting
6005
87L Current Differential Phase Percent Restraint 1
6006
87L Current Differential Phase Percent Restraint 2
6007
87L Current Differential Phase Dual Slope Breakpoint
6008
87L Current Differential Ground Function
6009
87L Current Differential Ground Pickup
600A
87L Current Differential Ground Restraint
600B
87L Current Differential Ground Delay
600C
87L Current Differential Key DTT
600D
87L Current Differential External Key DTT
600E
87L Current Differential Target
600F
87L Current Differential Event
6010
87L Current Differential Tap 2 Setting
6011
87L Current Differential Signal Source 2
6012
87L Current Differential Signal Source 3
6014
87L Current Differential Signal Source 4
Wattmetric ground fault settings (read/write grouped, 2 modules)
6050
Wattmetric ground fault 1 function
6051
Wattmetric ground fault 1 source
6052
Wattmetric ground fault 1 voltage
6053
Wattmetric ground fault 1 overvoltage pickup
6054
Wattmetric ground fault 1 current
6055
Wattmetric ground fault 1 overcurrent pickup
6056
Wattmetric ground fault 1 overcurrent pickup delay
6057
Wattmetric ground fault 1 power pickup
6058
Wattmetric ground fault 1 ECA
6059
Wattmetric ground fault 1 power pickup delay
605A
Wattmetric ground fault 1 curve
605B
Wattmetric ground fault 1 multiplier
605C
Wattmetric ground fault 1 block
605D
Wattmetric ground fault 1 target
605E
Wattmetric ground fault 1 events
605F
Wattmetric ground fault 1 reference power
6060
Reserved
6061
...Repeated for wattmetric ground fault 2
Wattmetric ground fault actual values (read only)
6072
Wattmetric ground fault 1 operating power
6074
Wattmetric ground fault 2 operating power
CT Failure Detector (Read/Write Setting)
6124
CT Fail Function
B-32
RANGE
0 to 5
---
---
---
---
---
---
0 to 1
0 to 65535
0 to 5
0.1 to 4
0.2 to 5
1 to 50
1 to 70
0 to 20
0 to 1
0.05 to 1
1 to 50
0 to 5
0 to 1
0 to 65535
0 to 2
0 to 1
0.2 to 5
0 to 6
0 to 6
0 to 6
0 to 1
0 to 5
0 to 1
0.02 to 3.00
0 to 1
0.002 to 30.000
0 to 600
0.001 to 1.2
0 to 360
0 to 600
0 to 5
0.01 to 2
0 to 65535
0 to 2
0 to 1
0.001 to 1.2
---
0.000 to 1000000.000
0.000 to 1000000.000
0 to 1
L90 Line Current Differential System
UNITS
STEP
FORMAT
---
1
F001
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
1
F102
---
1
F300
---
1
F167
pu
0.01
F001
---
0.01
F001
%
1
F001
%
1
F001
pu
0.1
F001
---
1
F102
pu
0.01
F001
%
1
F001
seconds
0.01
F001
---
1
F102
---
1
F300
---
1
F109
---
1
F102
---
0.01
F001
---
1
F211
---
1
F211
---
1
F211
---
1
F102
---
1
F167
---
1
F234
pu
0.01
F001
---
1
F235
pu
0.001
F001
s
0.01
F001
pu
0.001
F001
° Lag
1
F001
s
0.01
F001
---
1
F236
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
pu
0.001
F001
---
---
---
W
0.001
F060
W
0.001
F060
---
1
F102
APPENDIX B
DEFAULT
0
(none)
(none)
(none)
(none)
(none)
(none)
0 (Disabled)
0
0 (SRC 1)
20
100
30
50
10
0 (Disabled)
10
25
10
1 (Enabled)
0
0 (Self-reset)
0 (Disabled)
100
0 (None)
0 (None)
0 (None)
0 (Disabled)
0 (SRC 1)
0 (Calculated VN)
20
(Calculated IN)
60
20
100
0
20
0 (Definite Time)
100
0
0 (Self-reset)
0 (Disabled)
500
---
0
0
0 (Disabled)