E.1.2 Implementation Table - GE L90 Instruction Manual

L90 line current differential system ur series
Hide thumbs Also See for L90:
Table of Contents

Advertisement

E.1 DEVICE PROFILE DOCUMENT
The following table identifies the variations, function codes, and qualifiers supported by the L90 in both request messages
and in response messages. For static (non-change-event) objects, requests sent with qualifiers 00, 01, 06, 07, or 08, will be
responded with qualifiers 00 or 01. Static object requests sent with qualifiers 17 or 28 will be responded with qualifiers 17 or
28. For change-event objects, qualifiers 17 or 28 are always responded.
Table E–2: IMPLEMENTATION TABLE (Sheet 1 of 4)
OBJECT
OBJECT
VARIATION
DESCRIPTION
NO.
NO.
1
0
Binary Input (Variation 0 is used to request
default variation)
1
Binary Input
2
Binary Input with Status
2
0
Binary Input Change (Variation 0 is used to
request default variation)
1
Binary Input Change without Time
E
2
Binary Input Change with Time
3
Binary Input Change with Relative Time
10
0
Binary Output Status (Variation 0 is used to
request default variation)
2
Binary Output Status
12
1
Control Relay Output Block
20
0
Binary Counter
(Variation 0 is used to request default
variation)
1
32-Bit Binary Counter
Note 1:
A default variation refers to the variation responded when variation 0 is requested and/or in class 0, 1, 2, or 3 scans. The default varia-
tions for object types 1, 2, 20, 21, 22, 23, 30, and 32 are selected via relay settings. Refer to the Communications section in Chapter 5
for details. This optimizes the class 0 poll data size.
Note 2:
For static (non-change-event) objects, qualifiers 17 or 28 are only responded when a request is sent with qualifiers 17 or 28, respec-
tively. Otherwise, static object requests sent with qualifiers 00, 01, 06, 07, or 08, will be responded with qualifiers 00 or 01 (for change-
event objects, qualifiers 17 or 28 are always responded.)
Note 3:
Cold restarts are implemented the same as warm restarts – the L90 is not restarted, but the DNP process is restarted.
E-4
REQUEST
FUNCTION
CODES (DEC)
1
(read)
22
(assign class)
1
(read)
22
(assign class)
1
(read)
22
(assign class)
1
(read)
1
(read)
1
(read)
1
(read)
1
(read)
1
(read)
3
(select)
4
(operate)
5
(direct op)
6 (
dir. op, noack)
1
(read)
7
(freeze)
8
(freeze noack)
9
(freeze clear)
10
(frz. cl. noack)
22
(assign class)
1
(read)
7
(freeze)
8
(freeze noack)
9
(freeze clear)
10
(frz. cl. noack)
22
(assign class)
L90 Line Current Differential System

E.1.2 IMPLEMENTATION TABLE

RESPONSE
QUALIFIER
FUNCTION
CODES (HEX)
CODES (DEC)
00, 01
(start-stop)
06
(no range, or all)
07, 08
(limited quantity)
17, 28
(index)
00, 01
129
(start-stop)
(response)
06
(no range, or all)
07, 08
(limited quantity)
17, 28
(index)
00, 01
129
(start-stop)
(response)
06
(no range, or all)
07, 08
(limited quantity)
17, 28
(index)
06
(no range, or all)
07, 08
(limited quantity)
06
129
(no range, or all)
(response)
07, 08
130
(limited quantity)
(unsol. resp.)
06
129
(no range, or all)
(response
07, 08
130
(limited quantity)
(unsol. resp.)
06
(no range, or all)
07, 08
(limited quantity)
00, 01
(start-stop)
06
(no range, or all)
07, 08
(limited quantity)
17, 28
(index)
00, 01
129
(start-stop)
(response)
06
(no range, or all)
07, 08
(limited quantity)
17, 28
(index)
00, 01
129
(start-stop)
(response)
07, 08
(limited quantity)
17, 28
(index)
00, 01
(start-stop)
06
(no range, or all)
07, 08
(limited quantity)
17, 28
(index)
00, 01
129
(start-stop)
(response)
06
(no range, or all)
07, 08
(limited quantity)
17, 28
(index)
APPENDIX E
QUALIFIER
CODES (HEX)
00, 01
(start-stop)
17, 28
(index)
see Note 2)
(
00, 01
(start-stop)
17, 28
(index)
(see Note 2)
17, 28
(index)
17, 28
(index)
00, 01
(start-stop)
17, 28
(index)
(see Note 2)
echo of request
00, 01
(start-stop)
17, 28
(index)
(see Note 2)
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents