GE L90 Instruction Manual page 561

L90 line current differential system ur series
Hide thumbs Also See for L90:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 7 of 57)
ADDR
REGISTER NAME
21B0
Breaker flashover 1 pickup delay
21B1
Breaker flashover 1 supervision phase A
21B2
Breaker flashover 1 supervision phase B
21B3
Breaker flashover 1 supervision phase C
21B4
Breaker flashover 1 block
21B5
Breaker flashover 1 events
21B6
Breaker flashover 1 target
21B7
Reserved (4 items)
21BB
...Repeated for breaker flashover 2
Breaker Arcing Current Actuals (Read Only Non-Volatile) (2 modules)
21E0
Breaker 1 Arcing Current Phase A
21E2
Breaker 1 Arcing Current Phase B
21E4
Breaker 1 Arcing Current Phase C
21E6
Breaker 1 Operating Time Phase A
21E7
Breaker 1 Operating Time Phase B
21E8
Breaker 1 Operating Time Phase C
21E9
Breaker 1 Operating Time
21EA
...Repeated for Breaker Arcing Current 2
Breaker Arcing Current Commands (Read/Write Command) (2 modules)
2224
Breaker 1 Arcing Current Clear Command
2225
Breaker 2 Arcing Current Clear Command
Passwords Unauthorized Access (Read/Write Command)
2230
Reset Unauthorized Access
Fault Location (Read Only) (5 modules)
2340
Fault 1 Prefault Phase A Current Magnitude
2342
Fault 1 Prefault Phase A Current Angle
2343
Fault 1 Prefault Phase B Current Magnitude
2345
Fault 1 Prefault Phase B Current Angle
2346
Fault 1 Prefault Phase C Current Magnitude
2348
Fault 1 Prefault Phase C Current Angle
2349
Fault 1 Prefault Phase A Voltage Magnitude
234B
Fault 1 Prefault Phase A Voltage Angle
234C
Fault 1 Prefault Phase B Voltage Magnitude
234E
Fault 1 Prefault Phase B Voltage Angle
234F
Fault 1 Prefault Phase C Voltage Magnitude
2351
Fault 1 Prefault Phase C Voltage Angle
2352
Fault 1 Phase A Current Magnitude
2354
Fault 1 Phase A Current Angle
2355
Fault 1 Phase B Current Magnitude
2357
Fault 1 Phase B Current Angle
2358
Fault 1 Phase C Current Magnitude
235A
Fault 1 Phase C Current Angle
235B
Fault 1 Phase A Voltage Magnitude
235D
Fault 1 Phase A Voltage Angle
235E
Fault 1 Phase B Voltage Magnitude
2360
Fault 1 Phase B Voltage Angle
2361
Fault 1 Phase C Voltage Magnitude
2363
Fault 1 Phase C Voltage Angle
2364
Fault 1 Type
2365
Fault 1 Location based on Line length units (km or miles)
2366
...Repeated for Fault 2
238C
...Repeated for Fault 3
23B2
...Repeated for Fault 4
23D8
...Repeated for Fault 5
GE Multilin
RANGE
0 to 65.535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 2
---
0 to 99999999
0 to 99999999
0 to 99999999
0 to 99999999
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 1
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 11
-3276.7 to 3276.7
L90 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
s
0.001
F001
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F109
---
---
F001
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
ms
1
F001
ms
1
F001
ms
1
F001
ms
1
F001
---
1
F126
---
1
F126
---
1
F126
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
---
1
F148
---
0.1
F002
DEFAULT
100
0
0
0
0
B
0 (Disabled)
0 (Self-Reset)
0
0
0
0
0
0
0
0
0
0 (No)
0 (No)
0 (No)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (NA)
0
B-15