B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 56 of 57)
ADDR
REGISTER NAME
Phasor Measurement Unit Calibration (Read/Write Setting)
EA88
PMU 1 Va Calibration Angle
EA89
PMU 1 Vb Calibration Angle
EA8A
PMU 1 Vc Calibration Angle
EA8B
PMU 1 Vx Calibration Angle
B
EA8C
PMU 1 Ia Calibration Angle
EA8D
PMU 1 Ib Calibration Angle
EA8E
PMU 1 Ic Calibration Angle
EA8F
PMU 1 Ig Calibration Angle
EA90
PMU 1 Sequence Voltage Shift Angle
EA91
PMU 1 Sequence Current Shift Angle
Phasor Measurement Unit Triggering (Read/Write Setting)
EAB0
PMU 1 User Trigger
Phasor Measurement Unit Current Trigger (Read/Write Setting)
EAB4
PMU 1 Current Trigger Function
EAB5
PMU 1 Current Trigger Pickup
EAB6
PMU 1 Current Trigger Pickup Time
EAB7
PMU 1 Current Trigger Dropout Time
EAB8
PMU 1 Current Trigger Block (3 items)
EABB
PMU 1 Current Trigger Target
EABC
PMU 1 Current Trigger Events
Phasor Measurement Unit df/dt Trigger (Read/Write Setting)
EAD8
PMU 1 df/dt Trigger Function
EAD9
PMU 1 df/dt Trigger Raise
EADA
PMU 1 df/dt Trigger Fall
EADB
PMU 1 df/dt Trigger Pickup Time
EADC
PMU 1 df/dt Trigger Dropout Time
EADD
PMU 1 df/dt Trigger Block (3 items)
EAE0
PMU 1 df/dt Trigger Target
EAE1
PMU 1 df/dt Trigger Events
Phasor Measurement Unit Frequency Trigger (Read/Write Setting)
EB00
PMU 1 Frequency Trigger Function
EB01
PMU 1 Frequency Trigger Low Frequency
EB02
PMU 1 Frequency Trigger High Frequency
EB03
PMU 1 Frequency Trigger Pickup Time
EB04
PMU 1 Frequency Trigger Dropout Time
EB05
PMU 1 Frequency Trigger Block (3 items)
EB08
PMU 1 Frequency Trigger Target
EB09
PMU 1 Frequency Trigger Events
Phasor Measurement Unit Power Trigger (Read/Write Setting)
EB28
PMU 1 Power Trigger Function
EB29
PMU 1 Power Trigger Active
EB2A
PMU 1 Power Trigger Reactive
EB2B
PMU 1 Power Trigger Apparent
EB2C
PMU 1 Power Trigger Pickup Time
EB2D
PMU 1 Power Trigger Dropout Time
EB2E
PMU 1 Power Trigger Block (3 items)
EB31
PMU 1 Power Trigger Target
EB32
PMU 1 Power Trigger Events
Phasor Measurement Unit Voltage Trigger (Read/Write Setting)
EB54
PMU 1 Voltage Trigger Function
EB55
PMU 1 Voltage Trigger Low Voltage
EB56
PMU 1 Voltage Trigger High Voltage
EB57
PMU 1 Voltage Trigger Pickup Time
B-64
RANGE
-5 to 5
-5 to 5
-5 to 5
-5 to 5
-5 to 5
-5 to 5
-5 to 5
-5 to 5
-180 to 180
-180 to 180
0 to 65535
0 to 1
0.1 to 30
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0.1 to 15
0.1 to 15
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
20 to 70
20 to 70
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0.25 to 3
0.25 to 3
0.25 to 3
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0.25 to 1.25
0.75 to 1.75
0 to 600
L90 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
°
0.05
F002
°
0.05
F002
°
0.05
F002
°
0.05
F002
°
0.05
F002
°
0.05
F002
°
0.05
F002
°
0.05
F002
°
30
F002
°
30
F002
---
1
F300
---
1
F102
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
Hz/s
0.01
F001
Hz/s
0.01
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
Hz
0.01
F001
Hz
0.01
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
pu
0.001
F001
pu
0.001
F001
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
pu
0.001
F001
pu
0.001
F001
s
0.01
F001
DEFAULT
0
0
0
0
0
0
0
0
0
0
0
0 (Disabled)
1800
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
25
25
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
4900
6100
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
1250
1250
1250
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
800
1200
10
GE Multilin