Compact IO™ Isolated HART Analog Input Module
Table 6-3 (General Configuration Bits)
To Select
CH0 HART Enable
CH1 HART Enable
CH2 HART Enable
CH3 HART Enable
Pass-Through Scheme
Reserved
1
When RTS is set to zero, all channels are acquired freely and independently with no idle time. A channel
configured at a high filter frequency can be acquired multiple times in the time that a single acquisition is made for a
channel configured at a lower filter frequency.
User' s Manual 0300215-03 Rev. A
Table 6-2b (Module Configuration)
Word
15
14
13
12
26
27
28
29
30
31
32
33

6.4.1 Real Time Sample Value (Word 0)

The real time sample value determines when the module will scan its input channels for
available data. After the channels are scanned, the data is made available to the PLC.
The valid range for the real time sample is 0
Note: The Real Time Sample rate must be greater than or equal to the slowest channel
step response time. See Table 6-5 to determine the proper RTS rate.
Note: The configuration file can also be modified through the control program, if
supported by the controller. For information on configuring the module using
RSLogix 500 (with MicroLogix 1500 controller), see Chapter 5; for RSLogix 5000
(CompactLogix controller), see Chapter 4.

6.4.2 General Configuration Bits (Word 1)

Word 1 is used to configure general module properties like enabling and disabling
HART, setting a HART handle time for HART messaging, and selecting one of three
scanning schemes for HART pass-through messages. The table below shows the
available settings for word 1.
Handle Timeout
Disable
Enabled
Disable
Enabled
Disable
Enabled
Disable
Enabled
Two Channel Scans
Once Per Module Scan
Every Channel Scan
Set to Zero
ETS
Disabled
Enabled
Bit
11
10
9
8
7
6
Channel 0 HART Slot Variables 0 & 1
Channel 0 HART Slot Variables 2 & 3
Channel 1 HART Slot Variables 0 & 1
Channel 1 HART Slot Variables 2 & 3
Channel 2 HART Slot Variables 0 & 1
Channel 2 HART Slot Variables 2 & 3
Channel 3 HART Slot Variables 0 & 1
Channel 3 HART Slot Variables 2 & 3
1
to 5000 ms (i.e. Enter a value of 0 to 5000).
Make these bit settings
15
14
13
12
11
10
0
1
0
1
0
0
0
1
1
0
0
0
1
5
4
3
2
1
0
9
8
7
6
5
4
3
Handle Timeout (1 to 255 sec)
0
1
0
1
Function
Defines Slot
Variables
Defines Slot
Variables
Defines Slot
Variables
Defines Slot
Variables
Defines Slot
Variables
Defines Slot
Variables
Defines Slot
Variables
Defines Slot
Variables
2
1
0