Keysight N2800A User Manual page 31

Keysight n2800a series infiniimax iii series probing system
Table of Contents

Advertisement

1
Break off a ZIF tip/handle combination from the packaging holder at the point shown in the
figure.
Figure 23 Five ZIF Tips on Packaging
2
Flux and tin the leads on the target DUT.
Figure 24 Preparing the DUT Leads
3
While holding the plastic form, form the ZIF tip wires to match the DUT's pitch and angle.
4
Flux the ZIF tip wires and DUT leads.
5
Position the ZIF tip with the gold traces facing up as shown in
re-flow the solder. This orients the tip so that it will properly mate with the probe head.
When soldering the tip to your DUT, use the tip handle to hold the tip. This allows you to position these
N OT E
small tips without damaging them.
Do not dwell on this solder joint.
CAUTION
InfiniiMax III Series Probes User's Guide
InfiniiMax III Probe Heads
Figure 25
and carefully
2
31