Instructions for use MASTERsurg LUX Wireless REF 1.009.1200
5 Operation | 5.5 Setting and executing program steps
Step
1
Activity
Marking
Symbol
Step
1
Activity
Marking
Symbol
Step
1
Activity
Free use
Symbol
5.5.2 Exemplary programme step sequences
Example 1: Factory setting
2
3
Pilot drilling Template
drilling
Example 2: Program steps that do not include the activity, "Cut thread",
and include the "Rinsing function" activity
2
3
Pilot drilling
Template
drilling
Example 3: Activity "Free use" as step 1, screw implant in manually
2
Marking
4
5
Thread cut-
Placing im-
ting
plant
5
4
Rinsing func-
Placing im-
tion
plant
3
Pilot drilling
42 / 76
6
7
Setting
Free use
closure cap
5
7
Setting clos-
Treatment
ure cap
completed
(can be set
from pro-
gram step 4)
4
5
Template drilling Treatment com-
pleted (can be
set from program
step 4)
8
Treatment
completed
(can be set
from pro-
gram step
4)