Instructions for use
ESTETICA E70 Vision / E80 Vision

Advertisement

Table of Contents
loading

Summary of Contents for KaVo ESTETICA E70 Vision

  • Page 1 Instructions for use ESTETICA E70 Vision / E80 Vision...
  • Page 2 Distributed by: Manufacturer: KaVo Dental Technologies, LLC Kaltenbach & Voigt GmbH 11727 Fruehauf Drive Bismarckring 39 Charlotte, NC 28273 USA 88400 Biberach Tel. 847-550-6800 Germany Fax 847-550-6825 www.kavo.com...
  • Page 3: Table Of Contents

    Product-specific ....................16 3 Product description ......................20 3.1 Treatment centre......................20 3.1.1 KaVo ESTETICA E70 Vision / E80 Vision T ............. 20 3.1.2 KaVo ESTETICA E70 Vision S ................21 3.1.3 KaVo ESTETICA E70 Vision / E80 Vision Cart ............22 3.2 Versions of the dentist element ..................
  • Page 4 Instructions for use ESTETICA E70 Vision / E80 Vision Table of contents 4 Operation..........................45 4.1 Switching on the device....................45 4.2 Move the dentist's unit ....................45 4.2.1 Moving the T table ....................45 4.2.2 Moving the S table ....................46 4.2.3...
  • Page 5 Instructions for use ESTETICA E70 Vision / E80 Vision Table of contents 4.12.1 Adjusting the instrument light ................4.12.1 Use physiological saline solution (optional accessory) ..........4.12.1 Charge the wireless foot control ................4.13Using instruments......................106 4.13.1 Holder logic......................106 4.13.2 Using suction hoses .................... 106 4.13.3 Using the three-function handpiece...............
  • Page 6 Instructions for use ESTETICA E70 Vision / E80 Vision Table of contents 4.20Service table 1568 (optional accessory) ................142 4.20.1 Moving the service table ..................143 5 Preparation methods DIN EN ISO 17664 ................145 6 Additional equipment and kits ................... 146 6.1 Device ..........................
  • Page 7: User Instructions

    Instructions for use ESTETICA E70 Vision / E80 Vision 1 User instructions | 1.1 User guide 1 User instructions 1.1 User guide Requirement Read these instructions prior to first startup to avoid misuse and prevent dam- age. 1.1.1 Abbreviations Explanation...
  • Page 8: Service

    For further information, please visit: www.kavo.com 1.3 Terms and conditions of warranty KaVo provides the final customer with a warranty that the product cited in the handover certificate will function properly and guarantees zero defects in the material or processing for a period of 12 months from data of purchase, subject...
  • Page 9: Damage In Transit

    Terms and Conditions, Art. 28). Outside Germany Note KaVo shall not be held liable for damage arising from transportation. The shipment must be checked on arrival. If the packaging is visibly damaged on delivery, please proceed as follows: 1. The recipient of the package must record the loss or damage on the delivery receipt.
  • Page 10: Information On The Packaging: Storage And Transportation

    Instructions for use ESTETICA E70 Vision / E80 Vision 1 User instructions | 1.4 Transportation and storage 1.4.3 Information on the packaging: Storage and transportation Note Please keep the packaging in case you need to return the product for servi- cing or repair.
  • Page 11: Safety

    Instructions for use ESTETICA E70 Vision / E80 Vision 2 Safety | 2.1 Description of safety instructions 2 Safety 2.1 Description of safety instructions 2.1.1 Warning symbol Warning symbol 2.1.2 Structure DANGER The introduction describes the type and source of the hazard.
  • Page 12 / dentist. For dental use only. The KaVo service table 1568 is an accessory of KaVo treatment centres that do not feature a dentist element mounted to the unit. The KaVo Service table 1568 serves as a support surface for the dentist during the treatment. The service table 1568 can be used as a support for trays and for attachment of the X-ray viewer 1440.
  • Page 13: General

    ISO 7494 featuring a dental chair in accordance with ISO 6875. This KaVo product is designed for use in dentistry only and may only be used by trained medical personnel. Any other type of use is not permitted.
  • Page 14 The product includes open source licences to a certain extent. The exact licens- ing conditions, liability disclaimers, concessions and instructions will be provided to you in the device software. KaVo offers to provide the source code on a CD ROM; efforts and costs incurred (e. g. costs for auxiliaries, transport and pro- cessing) will be invoiced in terms of an expense allowance.
  • Page 15: Safety Instructions

    DANGER Explosion hazard. Risk of fatal injury. ▶ Do not use KaVo product in areas subject an explosion hazard. WARNING Inappropriate operating conditions. Impairment of the electrical safety of the device. ▶ It is essential to comply with the operating conditions specified in the "Technical Specifications"...
  • Page 16: Product-Specific

    Instructions for use ESTETICA E70 Vision / E80 Vision 2 Safety | 2.3 Safety instructions CAUTION Risks from electromagnetic fields. Electromagnetic fields might interfere with the functions of implanted systems (such as pacemakers). ▶ Ask patients if they have a cardiac pacemaker or other system implanted...
  • Page 17 Instructions for use ESTETICA E70 Vision / E80 Vision 2 Safety | 2.3 Safety instructions CAUTION Electrical power. Electrical shock from incorrectly connecting a non-medical system to the USB interfaces of the device. ▶ Connect any IT device to the medical system in accordance with IEC 60601-1.
  • Page 18 Instructions for use ESTETICA E70 Vision / E80 Vision 2 Safety | 2.3 Safety instructions CAUTION Third-party device connection assembly kit (optional): Risk of reverse contamination by stagnant water. Infections. If a water consumer is connected to the third-party device connection as- sembly kit, always perform the following actions on the device: ▶...
  • Page 19 Instructions for use ESTETICA E70 Vision / E80 Vision 2 Safety | 2.3 Safety instructions CAUTION Risk of injury when the dental chair or headrest is moved. Hair of the patient or practice personnel may get caught when the headrest of the dental chair is moved.
  • Page 20: Product Description

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.1 Treatment centre 3 Product description The ESTETICA Dental Treatment Unit and Accessories serves as a base that in- cludes components to deliver air, water, electrical power, and vacuum to dental handpieces, instruments, and accessories.
  • Page 21: Kavo Estetica E70 Vision S

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.1 Treatment centre 3.1.2 KaVo ESTETICA E70 Vision S ① Patient element ② Assistant element ③ Headrest ④ Backrest ⑤ Operating light ⑥ Dentist element ⑦ Seat ⑧...
  • Page 22: Kavo Estetica E70 Vision / E80 Vision Cart

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.1 Treatment centre 3.1.3 KaVo ESTETICA E70 Vision / E80 Vision Cart ① Patient element ② Assistant element ③ Headrest ④ Backrest ⑤ Operating light ⑥ Dentist element ⑦...
  • Page 23: Versions Of The Dentist Element

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.2 Versions of the dentist element 3.2 Versions of the dentist element 3.2.1 T table Note The holder assignment and arrangement of the instruments can be changed as needed and does not have to follow the picture.
  • Page 24: S-Table (Estetica E70 Vision Only)

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.2 Versions of the dentist element 3.2.2 S-Table (ESTETICA E70 Vision only) Note The holder assignment and arrangement of the instruments can be changed as needed and does not have to follow the picture.
  • Page 25: Cart

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.2 Versions of the dentist element 3.2.3 Cart Note The holder assignment and arrangement of the instruments can be changed as needed and does not have to follow the picture.
  • Page 26: Assistant Unit

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.3 Assistant unit 3.3 Assistant unit Note The holder assignment and arrangement of the instruments can be changed as needed and does not have to follow the picture.
  • Page 27: Multifunctional Handpiece (Mf Handpiece)

    ④ Labelled gold: Multifunctional hand- piece (MF handpiece) ⑤ Cannula 3.6 X-ray viewer 1440 X-ray viewer 1440 Note The KaVo X-ray viewer 1440 is a type 1 radiological viewing device in accord- ance as defined in DIN 6856-3. 27 / 178...
  • Page 28: Control Elements

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.7 Control elements 3.7 Control elements 3.7.1 Dentist element T-table and cart Touchscreen E70 Vision / E80 Vision ① Tab "Treatment" ② Tab "Timer" ③ Tab "CONEXIO" (optional) ④...
  • Page 29: Dentist's Unit S Table

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.7 Control elements 3.7.2 Dentist's unit S table Tab "Treatment" ① Direct keys "Chair functions" ② "Most recent position" und "Rinse position" keys ③ Display "Time of day"...
  • Page 30: Assistant Element

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.7 Control elements 3.7.3 Assistant element ① Direct keys "Chair functions" ② "Last position" key ③ "Rinse position" key ④ "Automatic positions" keys ⑤ "Timer" keys ⑥ "Bowl rinsing" key ⑦...
  • Page 31 Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.7 Control elements Name "LP" key (last position) "AP 1" key (automatic position 1) "AP 0" key (automatic position 0) "AP 2" key (automatic position 2) "Collapsed position" key "Chair up"...
  • Page 32: Foot Control

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.8 Foot control Direct keys (selectable in "Settings" tab) Name Control element "Tumbler filler" key Dentist element and assistant element "Bowl rinsing" key Dentist element and assistant element "Bell"...
  • Page 33: Rating Plate And Name Plate

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.9 Signs on the product 3.9.2 Rating plate and name plate Note The body base, the dental element and the chair always have the same serial number.
  • Page 34 Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.9 Signs on the product Manufacturing date Can be sterilised at up to 135°C _V _Hz Supply voltage, frequency, power Rating plate on the base of the unit...
  • Page 35 Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.9 Signs on the product Rating plate and labelling on dentist and assistant elements Mounting location of rating plate and applied part mark on dentist and assistant elements...
  • Page 36 Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.9 Signs on the product Nameplate: wireless foot control The wireless foot control nameplate is located on its underside. Labelling and marking of the three-function handpiece and multifunctional handpiece...
  • Page 37 Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.9 Signs on the product ① Device type ② Material number ③ Year and month manufactured - ④ HIBC Code Serial number ⑤ Read and take note of the content ⑥...
  • Page 38: Technical Data

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.10 Technical data 3.10 Technical data Electrical system Maximum power consumption 100 to 1200 VA (100 to 230 V) Heat emission 360 to 4320 kJ/h (100 to 230 V)
  • Page 39 Note In conjunction with the "DVGW water block with integrated water germ re- duction" a water germ reduction unit is installed in dental units from KaVo. The germ reduction liquid OXYGENAL 6 cleaner is continually added to the water at a concentration which is harmless for persons, but hygienically ef- fective to maintain the quality of the treatment water by making it more diffi- cult for microorganisms to multiply and spread.
  • Page 40 Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.10 Technical data WARNING There is a risk of infection if you fail to comply with national regula- tions. Contamination of the treatment water and/or drinking water supply with germs.
  • Page 41 Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.10 Technical data Air inlet pressure 5.2 to 7 bar (0.52 to 0.7 MPa) Minimum air flow rate min. 80 Nl/min Pressure dew point < -30 ºC (compressor with...
  • Page 42: Transportation And Storage Conditions

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.10 Technical data Operating environment WARNING Inappropriate operating conditions. Impairment of the electrical safety of the device. ▶ It is essential to comply with the operating conditions specified in the "Technical Specifications"...
  • Page 43 Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.10 Technical data Weight ESTETICA E70 Vision Table T E70 Vision gross 47 kg/net 29 kg Table S E70 Vision gross 43 kg/net 28 kg Table C E70 Vision...
  • Page 44: Kavo Service Table 1568 (Optional Accessory)

    Instructions for use ESTETICA E70 Vision / E80 Vision 3 Product description | 3.11 KaVo Service table 1568 (optional accessory) Operating light KaVoLUX 540 LED See also: 2 Instructions for Use KaVoLUX 540 LED 3.11 KaVo Service table 1568 (optional accessory) ①...
  • Page 45: Operation

    Always switch the machine off before leaving the office. ▶ Switch on the device using the main switch. ð The KaVo log is illuminated on the display of the dentist element. ð A melody is hears as soon as the unit has completely been started up.
  • Page 46: Moving The S Table

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.2 Move the dentist's unit ▶ Release the handle. ð The support arm automatically brakes. The dentist element is difficult to move. 4.2.2 Moving the S table CAUTION Risk of injury by suspended instruments (S table).
  • Page 47: Move The Cart

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.2 Move the dentist's unit 4.2.3 Move the cart CAUTION Moving and overloading the cart. Danger of tipping and damaging the cart. ▶ Only use the card on a continuously smooth floor.
  • Page 48: Moving The Assistant Element

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.3 Moving the assistant element 4.3 Moving the assistant element NOTICE Damage from overloading the assistant's unit Exceeding the maximum load from mounting instruments, accessories, etc. can cause damage.
  • Page 49: Attaching The Tray Holder (Optional Assembly Kit)

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.4 Move patient chair 4.3.1 Attaching the tray holder (optional assembly kit) ▶ Mount the tray holder on the assistant element. ① Tray support ② Tray holder The support ② for the tray holder ①is an optional accessory.
  • Page 50: Adjusting The Patient Chair

    Direct contact between the skin of the patient and the cushion during patient positioning To improve hygiene and increase the service life, KaVo recommends to use ap- propriate covers (e.g. head protection bags) to protect the cushions that are regularly in contact with the skin of the patient. Sweat or hair and skin care products can be a serious strain on the cushions.
  • Page 51: Adjusting The Comfort Backrest

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.5 Adjusting the patient chair ▶ Then swivel the arm rest back into place. 4.5.2 Adjusting the Comfort backrest ▶ Press the button to adjust the backrest height.
  • Page 52 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.5 Adjusting the patient chair Function Move to most recent position before actuation of the Move to automatic position 0. Move to automatic position 1. Move to automatic position 2.
  • Page 53: Manually Positioning The Patient Chair

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.5 Adjusting the patient chair Note The memory is erased when you turn off the device. After turning on the device again (for example in the morning or after lunch), the chair does not execute a specific movement when you press the "LP"...
  • Page 54 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.5 Adjusting the patient chair If the desired function level is not activated, press the "Mode" key. Please refer to: Setting the function level Use the following buttons to adjust the chair height and position of the back-...
  • Page 55: Moving The Patient Chair

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.6 Moving the patient chair 4.6 Moving the patient chair 4.7 Adjust the motorised headrest The motorised support for the headrest allows you to optimally situate the pa- tient with easy manual manipulations.
  • Page 56: Adjusting The Motorised Headrest With The Joystick

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.7 Adjust the motorised headrest Dentist unit key Assistant unit key Function The bar is being exten- ded. The bar is being com- pressed. The headrest tilts for- ward.
  • Page 57 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.7 Adjust the motorised headrest ▶ Press joystick switch ①. ð Signal sound is emitted. Compensation is turned off. Five display diodes of the "AP" keys are flashing. All axes can be independently operated using the joystick switch ①.
  • Page 58: Automatically Position The Motorised Headrest

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.8 Adjusting double-jointed headrests 4.7.2 Automatically position the motorised headrest When you save the automatic chair positions, the angle of the headrest is also saved. ▶ After selecting the automatic position, you can manually adjust the head- rest if desired.
  • Page 59 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.8 Adjusting double-jointed headrests ▶ Evenly pull the cushion up and rotate it 180 ▶ Then snap the head cushion back on. 59 / 178...
  • Page 60: Safety Shut-Off

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.9 Safety shut-off 4.9 Safety shut-off The safety shutoffs are provided to protect the patient and office staff from in- jury and the treatment unit from damage. The safety cut-offs can be found at the following places on the treatment unit.
  • Page 61 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.9 Safety shut-off Pos. Safety shutoff actuated Display LED on the assistant element ② Inner side cover B E70 Vision: Inner side cover A E80 Vision: Support cover ③...
  • Page 62: Using Functions Through The Touchscreen

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen CAUTION Danger of crushing when retracting the patient chair with activated safety shutoff. The patient can be clamped in. ▶ Only retract the patient chair without the patient.
  • Page 63 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Menu Description Timer ▪ Open the timer ▪ Setting the timer CONEXIO (optional) Data processing and communica- tion with office software Cleaning ▪...
  • Page 64: Selecting The Dentist

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Symbol Function Description "Decrease value" button Press the "Decrease value" key to decrease a value. "Save" icon Tap the "Save" key to save changes.
  • Page 65 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Handpiece-specific settings The various types of treatment and the handpiece-specific values can be dis- played and set in the "Treatment" menu. The display depends on which instrument was withdrawn.
  • Page 66 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen ▶ Select the type of treatment from the list as desired to display the values. ▶ Tap the "Edit" key to edit the parameter values.
  • Page 67 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen See also: 2 4.16 Use pump for physiological saline (optional accessory), Page 133 ▶ After you set a single value or all values, tap the "Save" key to save the val- ues.
  • Page 68 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen ▶ After you set a single value or all values, tap the "Save" key to save the val- ues. Settings for the PiezoLED Note Please comply with the enclosed "PiezoLED"...
  • Page 69 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Symbol Function No cooling Spray water cooling Dosing the amount of spray water CAUTION Lack of working tip cooling. Heat damage to tooth or handpiece.
  • Page 70 KaVo KEY Laser III or KEY Laser 3+ can lead to the unintentional activation of the KaVo KEY Laser III and KEY Laser 3+. ▶ When using the KaVo KEY Laser III or the KEY Laser 3+, switch the operat- ing light to laser mode.
  • Page 71 KaVo DIAGNOdent can lead to faulty measurements. ▶ Switch the operating light to laser mode when using the KaVo DIAGNOdent. ▶ Or switch off the operating light, do not use KaVo DIAGNOdent and operat- ing light KaVoLUX 540 LED simultaneously. CAUTION Premature hardening of composite fillings.
  • Page 72 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Turning the operating light On and Off Sensor KaVoLUX 540 LED ▶ Tap the "Operating light" key. ▶ Hold your hand just in front of the sensor.
  • Page 73 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen ▶ Set the colour temperature using the "Colour temp". einstellen. Set the brightness and type of dimming ▶ Tape the "Dim mode" key to toggle between COMPOsave and Dim mode.
  • Page 74 Therefore a colour comparison should not be carried out in laser mode. In laser mode, another light mode is generated, which has no negative influ- ence on the KaVo KEY Laser III, the KEY Laser 3+ or the KaVo DIAGNOdent. 74 / 178...
  • Page 75 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Sensor KaVoLUX 540 LED ▶ Tap the "Laser" key (can be added via Settings on home screen). ð The laser mode switches on.
  • Page 76: Timer Menu

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Operation of the 3D joint ▶ Turn the switching ring to the left until it snaps into place. ð Treatment light can be rotated 45° to the left or 45° to the right.
  • Page 77: Conexio Menu

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen ▶ Tap the timer again to stop the timer. Note The activated timer times are also displayed on the touchscreen. If several timer times are running simultaneously, this is displayed in the se- quence of when they elapse.
  • Page 78 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen See also: 2 CONEXIO installation instructions Note To be able to use the CONEXIO tab, CONEXIO must be installed on a work- station computer and connected to the practice network (CONEXIO unit).
  • Page 79 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Presentation Icon Presentation Feature Presentation of the images in "list view" Presentation of the images in "tile view" Single image presentation Two image presentation...
  • Page 80 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Note CONEXIO can show only those patients who have been entered in the CON- EXIO database. Patient files can be transferred to the treatment centre by one of 3 ways: 1.
  • Page 81 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Image viewing mode Requirement Image or images are marked. ▶ Tap arrow key to switch to viewing mode. A single or multiple image view (up to 6 images) is possible in the image view- ing mode.
  • Page 82 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen ▶ Tap image again to cancel the selection. Note In multiple image display, the selected image can be magnified or made smaller.
  • Page 83 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Note In the image viewing mode, the images created in live view will be displayed in the most recent available windows. Automatically, a display is selected in which all selected images of the database and the "live"...
  • Page 84 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Note To be able to navigate in the "CONEXIO" menu with the foot control, the "CONEXIO" menu must be open or an imaging device activated. When you switch to the "CONEXIO"...
  • Page 85: Hygiene Functions

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen 4.10.6 Hygiene functions ▶ Tap the "Cleaning" tab to open the "Cleaning" menu. The following buttons are available for the hygiene functions:...
  • Page 86: Cleaning Menu

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen "Set the tumbler filling time" view ▶ Confirm tumbler filling time by saving once the desired filling level is reached. ▶ Tap "x" to quit without saving.
  • Page 87: Using Other Functions

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen See also: 2 Servicing instructions E70 Vision / E80 Vision 4.10.8 Using other functions. The following other keys are available for operation:...
  • Page 88 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen User settings ▶ Tap the "DELETE USER" key to delete a user. ▶ Tap the "Back" key to switch to user overview.
  • Page 89 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Lamp settings ▶ Tap the "Home screen" key to configure the home screen with up to six dir- ect keys. ▶ Draw the respective key to where you want it.
  • Page 90: Advanced Settings

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Global settings / Display Sounds and volume ▶ Tap the "Sounds and volume" key to set the key sounds and the volume.
  • Page 91 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen ▶ Tap the "Status after switch on" to define the "practitioner" and the "type of treatment" to be selected after the unit has been switched on.
  • Page 92 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen ▶ Tap the " Tumbler & bowl" key to make the following settings: - Automatic bowl rinsing - Tumbler filling and tumbler sensor...
  • Page 93 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen ▶ Tap the "Operating light" key to set the automatic activation of the operat- ing light. Advanced settings / Operating light ▶ Tap the "Weekly cleaning" key to make the following settings: - Weekly cleaning - Handpiece rinsing time in "Mornings"...
  • Page 94 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.10 Using functions through the touchscreen Global settings / Information ▶ Tap the "Device information" key to display information about the device. Information / Device information ▶ Tap the "system check" key to open the system check.
  • Page 95: Using The Functions Through The Assistant Unit Controls

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.11 Using the functions through the assistant unit controls 4.11 Using the functions through the assistant unit controls 4.11.1 Using the chair functions CAUTION Motorised movement of the chair The patient or treatment personnel can be clamped or crushed.
  • Page 96: Using The Light Functions

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.11 Using the functions through the assistant unit controls Function Bowl flushing The bowl is being rinsed. The flushing time can be changed. When the rinsing position (SP) is reached, the bowl is rinsed for the complete rinsing time, i.e., the bowl...
  • Page 97: Using The Foot Control

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.12 Using the foot control 4.12 Using the foot control 4.12.1 General functions The footswitches of the foot control have two functions. The function of the con- trol depends on whether an instrument is in its holder or whether it has been removed.
  • Page 98 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.12 Using the foot control Rear of the wireless foot control Item Labelling Function LED display Status display / charge status dis- ① play On/Off switch On/off switch to prevent deep dis- ②...
  • Page 99: Create A Connection Between The Wireless Foot Control And Treatment Unit

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.12 Using the foot control CAUTION Critical battery level If the battery reaches a critical charge status, a signal is sounded every time a function key is pressed.
  • Page 100 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.12 Using the foot control ▶ Use the "Up" or "Down" keys to select the menu item "Login", and activate with the "Confirm" key. ð Synchronisation starts. The currently set channel is displayed.
  • Page 101: Position The Patient Chair With The Foot Control

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.12 Using the foot control Example of the identification of the wireless foot control CAUTION Improper use of the wireless foot control Damage or malfunction ▶ In case of improper use (such as cleaning), turn off the wireless foot control or the treatment unit.
  • Page 102: Pre-Selecting The Type Of Treatment

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.12 Using the foot control Reassign "SP" or "LP" foot buttons ▶ Hold down the foot control and foot-operated button "SP", and simultan- eously press any button for an automatic position (SP, LP, AP 0 to AP 3 or collapsed position) on the dentist or assistant element until you hear a tone.
  • Page 103: Preselect Dentist

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.12 Using the foot control 4.12.6 Preselect dentist ▶ Hold down the foot pedal and press the stirrup switch (with handpieces stored). ð Up to six users can be programmed. This can be set in "User" in the "Set- tings"...
  • Page 104: Setting The Cooling Condition

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.12 Using the foot control 4.12.8 Setting the cooling condition ▶ Remove the handpiece (such as turbine, motor) from the holder ð The handpiece is active. ▶ Press "Preselected spray" footswitch.
  • Page 105: Charge The Wireless Foot Control

    ▶ Charge the wireless foot control with the charger supplied only. Note Charge the wireless foot control with the charger supplied by KaVo only. Note The wireless foot control charger may only be used indoors and must be pro- tected from moisture.
  • Page 106: Using Instruments

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.13 Using instruments 4.13 Using instruments Note Consult the separate instructions for the installation, operation and mainten- ance of the individual handpieces (such as the turbine, COMFORTdrive, cam- era, Satelec Mini LED, PiezoLED etc.).
  • Page 107 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.13 Using instruments Vacuum stop CAUTION Danger of backflow Swallowing or choking hazard for the patient ▶ Only actuate the vacuum stop when the suction cannula is not in the pa- tient's mouth.
  • Page 108: Using The Three-Function Handpiece

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.13 Using instruments 4.13.3 Using the three-function handpiece CAUTION Cannula that is worn or not locked into place. Injury from swallowing the cannula. ▶ Before each treatment, ensure that the cannula is locked into place and firmly seated.
  • Page 109: Using The Multifunctional Handpiece

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.13 Using instruments ▶ Simultaneously press the air button ① and water button ④ and continu- ously increase or decrease the exiting spray by applying more or less pres- sure on the two buttons.
  • Page 110 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.13 Using instruments ① Air button (A) ② Cannula ③ Grip sleeve ④ Water button (W) ⑤ Ring gold Note Cannulas can be rotated by 360 The "on" time for the handpiece with heating is 5 minutes with a resting time of 3 minutes.
  • Page 111 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.13 Using instruments Using the cold light Requirement The light and heating are preselected. ▶ Setting the cold light intensity. ▶ Press the air button ① and/or the water button ②.
  • Page 112: Using The Piezoled

    To ensure proper function, the poles need to be in- serted correctly. ▶ Push the holder ③ forward and pull the defective KaVo MULTI LED lamp ② out of the socket. ▶ Insert new Kavo MULTI LED lamp (Mat. no. 1.007.5372).
  • Page 113: Using The Kl 703 Led In Endo Mode (Optional Accessory)

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.14 Using the KL 703 LED in ENDO mode (optional accessory) CAUTION Sharp-edged tips. Risk of injury. ▶ When not in use, always keep the supplied torque wrench attached to the...
  • Page 114 ▶ Use root canal instruments in ENDO mode only. Note The control of the device is matched to the efficiency of the KaVo handpieces. Speed and torque can be assured only with the following KaVo handpieces. ▶ Only use KaVo-approved handpieces with a transmission ratio of 1:1, 3:1 or 8:1.
  • Page 115: Setting The Storage Position Of The Endo-Motor

    The INTRA LUX KL 703 LED motor has a maximum torque range from 0.15 to 3 Ncm. If the torque is in excess of 2.0 Ncm, KaVo recommends using a reducing contra-angle handpiece 3:1 or 8:1 in order to reduce the load on and heating of the motor.
  • Page 116: Open Endo Mode

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.14 Using the KL 703 LED in ENDO mode (optional accessory) 4.14.3 Open ENDO mode ▶ Take the INTRA LUX Motor KL 703 endomotor off the holder. ▶ Unfold the "Type of treatment" selection list and select "Endodontics".
  • Page 117: File Database

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.14 Using the KL 703 LED in ENDO mode (optional accessory) 4.14.5 File database The ESTETICA E70/E80 Vision has an integrated file database in the en- dodontics mode (optional accessories). It is necessary to check if the file data are up-to-date by comparing them to the respective manufacturer information.
  • Page 118 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.14 Using the KL 703 LED in ENDO mode (optional accessory) ▶ Tap the "Pen" control element to edit the sequence. ð The display shows file sequence "Profile 1" in editing mode.
  • Page 119 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.14 Using the KL 703 LED in ENDO mode (optional accessory) ▶ Tap the third column called "Size" and use the arrow keys to select the file geometry.
  • Page 120 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.14 Using the KL 703 LED in ENDO mode (optional accessory) ▶ All other data must be set manually by the user according to the informa- tion provided by the file manufacturer. For this purpose, tap on the corres- ponding column and use the arrow keys to select the desired data value (torque, speed, file colour).
  • Page 121 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.14 Using the KL 703 LED in ENDO mode (optional accessory) If the set speed differs from the recommended value of a file, a greyed-out factory symbol is shown.
  • Page 122 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.14 Using the KL 703 LED in ENDO mode (optional accessory) When the set torque is reached, the motor switches to counterclockwise rota- tion. ▶ To stop this, release the foot pedal.
  • Page 123: Exiting From The Type Of Treatment "Endodontics

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.15 Using the SL600 surgical motor (optional accessory) Note The motor's rotational direction can be reversed with the cross-switch on the footswitch in all torque modes. 4.14.7 Exiting from the type of treatment "Endodontics"...
  • Page 124: Connecting And Operating The Pump For Physiological Saline

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.15 Using the SL600 surgical motor (optional accessory) Mode Note 30 seconds operating time/9 minutes pause is the potential load threshold of the motor (full load at maximum speed).
  • Page 125: Calling-Up The Surgery Mode

    ▶ Pull on the KaVo handpiece to make sure that it is securely attached to the motor. 125 / 178...
  • Page 126: Start-Up The Motor

    The user should always check if the displayed transfer ratio is correct before turning on the device. Note The torque values can deviate by max. ± 10 % with the KaVo contra-angle handpieces SURGmatic S201. Larger deviations are possible with other con- tra-angle handpieces.
  • Page 127 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.15 Using the SL600 surgical motor (optional accessory) Type of treatment Surgery | Programme steps ① Current programme step ② Activity assigned to the programme step The current programme step ① and the corresponding activity are shown as symbol ②.
  • Page 128 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.15 Using the SL600 surgical motor (optional accessory) ▶ Hold down the "Blown air" foot-operated button for a while. Setting and saving parameters ▶ Selecting the working step to be changed.
  • Page 129 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.15 Using the SL600 surgical motor (optional accessory) Activity Step Icon Speed Torque Transmis- [rpm] [Ncm] sion ratio Form drilling 2 200 – 2,000 5 – 20 500 (D)
  • Page 130: Using The Surgical Motor With "Free Application" Activity

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.15 Using the SL600 surgical motor (optional accessory) Activity Step Icon Speed Torque Transmis- [rpm] [Ncm] sion ratio Free use 300 – 0.1 – 5.5 40,000 3 (D) 40,000 (D) 300 –...
  • Page 131 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.15 Using the SL600 surgical motor (optional accessory) Setting the torque Note The torque values are only for KaVo handpieces and angle pieces that oper- ate properly. ▶ Tap Current torque (value in Ncm). ð...
  • Page 132: Setting The Operating Light (Lux)

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.15 Using the SL600 surgical motor (optional accessory) 4.15.9 Setting the operating light (LUX) Spot light ▶ Push the cross-switch to the right to activate the light (without the motor and pump running).
  • Page 133: Exit Surgery Mode

    4 Operation | 4.16 Use pump for physiological saline solution (optional accessory) Note One-touch calibration should be carried out only with KaVo surgical hand- pieces with a transmission ratio of 16:1 or 20:1. The one-touch calibration cannot be run with third-party handpieces or hand- pieces with different transmission ratios.
  • Page 134: General Information

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.16 Use pump for physiological saline solution (optional accessory) 4.16.1 General information CAUTION Running, open hose pump. Risk of injury. ▶ Turn off the device before opening the hose pump.
  • Page 135: Connecting The Coolant

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.16 Use pump for physiological saline solution (optional accessory) Icon Description Expiry date Batch number Sterilisation method Single use 4.16.2 Connecting the coolant Note All liquid-conducting parts are not sterile. They must be sterilised before the first treatment.
  • Page 136: Connect Coolant To Instrument (General)

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.16 Use pump for physiological saline solution (optional accessory) 4.16.3 Connect coolant to instrument (general) ▶ Route the coolant hose ③ from the unit along the motor lead (clips) and connect it to the straight or contra-angle handpiece ⑤.
  • Page 137 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.16 Use pump for physiological saline solution (optional accessory) ① Coolant hose ② Clip ③ Hose clamp ④ Lock ⑥ Insertion needle ▶ Close the hose clamp ③ of the hose set.
  • Page 138: Turn On Pump And Regulate

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.16 Use pump for physiological saline solution (optional accessory) Note Make sure to place the pump hose in the pump appropriately such that the pump hose does not get clamped or pinched by the lock. Route all hoses re- laxed and without tension.
  • Page 139: After Treatment: Disposal

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.16 Use pump for physiological saline solution (optional accessory) ▶ Pull the hose and puncture needle out of the empty coolant container. ▶ Replace the empty coolant container by a full coolant container.
  • Page 140: Using The Comfortdrive 200 Xd/Comfortbase (Optional Accessory)

    200,000 rpm. It can be attached only to the KaVo COMFORTbase coupling. The hose of the KaVo COMFORTbase is part of the coupling and cannot be re- moved! Operation and changing the settings via the control element is identical to the INTRA LUX motor KL 703.
  • Page 141: Replacing The High-Pressure Bulb Of The Comfortbase

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.18 Use USB interface 4.17.4 Replacing the high-pressure bulb of the COMFORTbase CAUTION Danger of burns from hot high-pressure lamp. ▶ Switch main device switch off. ▶ Let the COMFORTbase cool down after long use.
  • Page 142: Using The Camera

    The treatment unit may be fitted with up to three USB ports. Camera interfaces are situated on the underside of the dentist element (T-table) or in the dentist element (S-table). Only the cameras approved/enclosed in the delivery by KaVo may be connected to these interfaces.
  • Page 143: Moving The Service Table

    Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.20 Service table 1568 (optional accessory) The service table 1568 can be locked in 4 snap-in positions using the rotary button ①. This locks only the downward movement to allow for higher loads.
  • Page 144 Instructions for use ESTETICA E70 Vision / E80 Vision 4 Operation | 4.20 Service table 1568 (optional accessory) Dimensions and swing ranges (in mm) 144 / 178...
  • Page 145: Preparation Methods Din En Iso 17664

    Instructions for use ESTETICA E70 Vision / E80 Vision 5 Preparation methods DIN EN ISO 17664 5 Preparation methods DIN EN ISO 17664 Note The preparation methods can be found in the care instructions. 145 / 178...
  • Page 146: Additional Equipment And Kits

    Instructions for use ESTETICA E70 Vision / E80 Vision 6 Additional equipment and kits | 6.1 Device 6 Additional equipment and kits Note The USB interfaces of the system may only be connected to IT devices ap- proved by KaVo.
  • Page 147 Instructions for use ESTETICA E70 Vision / E80 Vision 6 Additional equipment and kits | 6.3 Dentist unit Name Description Physiological saline solution For aseptic bur cooling during surgical work, an assembly kit for physiological saline is available. Surgical motor For surgical work.
  • Page 148: Safety Check - Test Instructions

    Note If several medical electrical devices (ME device) or electrical devices from several manufacturers combined into a system are connected to the KaVo dental unit, the manufacturer data contained in the instructions for use for all products subject to the safety checks must also be noted.
  • Page 149: Notes Concerning Medical Electrical Systems

    7 Safety check - Test instructions | 7.1 Introduction Note KaVo offers a medical device book for keeping an inventory and recording es- sential master data on the medical device. The medical device book is only available in German (Mat. no. 0.789.0480).
  • Page 150: Components Of The Safety Check

    Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.1 Introduction Note If it should be impossible to check single ME devices that are functionally connected to an ME system individually for technical reasons, the ME system must be checked as a whole.
  • Page 151: Notes On Repeat Tests

    Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.2 Instructions for the safety check 7.1.6 Notes on repeat tests Note The value determined in these tests must be documented and evaluated to- gether with the measuring processes.
  • Page 152: Visual Inspection

    Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.2 Instructions for the safety check ▶ Release the service flap ⑧ below and remove. ▶ Remove screw ⑨. ▶ Release the left side cover ① below and remove.
  • Page 153 Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.2 Instructions for the safety check Check of safety-related labels for legibility and completeness ▶ Check if all safety-related markings (plates and labels) are present and legible.
  • Page 154: Measurements

    Connection cables such as data cables and cables for the functional earth could simulate protective conductor connections. These types of supplement- ary but unintentional protective earth connections could lead to erroneous measurements. Note The following measuring aids can be ordered: KaVo measuring cable (Mat. no. 0.411.8811) 154 / 178...
  • Page 155 ▶ Remove plug X2 from the power input board and plug it into the matching connector X2 of the KaVo- measuring cable (Mat. no. 0.411.8811). ▶ Plug the second plug X2 of the KaVo measuring cable into the network card (X2).
  • Page 156 Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.2 Instructions for the safety check Note The main switch of the ME device / ME system must be turned on during the measurement.
  • Page 157 Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.2 Instructions for the safety check ▶ Connect TP2 measuring socket ① to the safety tester. ▶ Connect① ultrasonic scaler tip to the safety tester.
  • Page 158 Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.2 Instructions for the safety check Note Additional measuring points ACP X must be taken into consideration in the presence of accessories. See also:...
  • Page 159 Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.2 Instructions for the safety check Protective earth measurement The protective conductor resistance must be measured at the following parts of the device: ▪ Treatment centre ▪...
  • Page 160 Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.2 Instructions for the safety check ① Backrest progress: backrest with ② Comfort backrest: fastening screw the upholstery removed ① Dentist element T: Fixing screw on ②...
  • Page 161 Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.2 Instructions for the safety check ① Arm with cover removed Scanning the treatment lamp with the test tip KaVoLUX 540 LED U operating light ①...
  • Page 162 Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.2 Instructions for the safety check Touch monitor with test tip: ▶ Scan the measuring point ① with the test tip. ▶ Scan the measuring point ② after removing the display cover.
  • Page 163: Functional Tests

    Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.2 Instructions for the safety check Applied part leakage current - Alternative measuring method Limit < 5 mA (maximum value!) Protection class 1 WARNING Electrical power.
  • Page 164 Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.2 Instructions for the safety check The following list is for exemplary purposes and makes no claim of being com- plete. ▪ Functional test of the safety circuits (see diagram below) ▪...
  • Page 165: Assessment And Documentation

    Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.2 Instructions for the safety check 7.2.5 Assessment and documentation Note All tests conducted must be documented comprehensively. The doc- uments must contain at least the following particulars: ▶...
  • Page 166: Test Protocol For The Safety Check

    Instructions for use ESTETICA E70 Vision / E80 Vision 7 Safety check - Test instructions | 7.3 Test protocol for the safety check 7.3 Test protocol for the safety check Unit leakage current - replacement measurement Leakage current of applied part - replacement...
  • Page 167: Appendix - Additional Measuring Sites

    Instructions for use ESTETICA E70 Vision / E80 Vision 8 Appendix - Additional measuring sites | 8.1 Additional scanning sites SL X in the protective conductor measure- ment 8 Appendix - Additional measuring sites Note With reference to accessories, which are not listed here, the specifications of the relevant instructions for use must be observed.
  • Page 168: Additional Measuring Sites Ap X For Eul/Epl Measurement

    Instructions for use ESTETICA E70 Vision / E80 Vision 8 Appendix - Additional measuring sites | 8.2 Additional measuring sites AP X for EUL/EPL measurement Ceiling adapter for operating light assembly kit ① Base plate for the ceiling adapter ② Surroundings of the protective con- ductor connector ③...
  • Page 169: Eliminating Disturbances

    Instructions for use ESTETICA E70 Vision / E80 Vision 9 Eliminating disturbances 9 Eliminating disturbances Note In case of malfunctions, consult the separate instructions for the use and care of the individual instruments (such as the turbine, motor, camera, Sate- lec Mini LED, etc.).
  • Page 170 Instructions for use ESTETICA E70 Vision / E80 Vision 9 Eliminating disturbances Malfunction Cause Remedy ▶ Check the safety shutoffs and eliminate the The patient chair does The safety shutoff is reason for the shutoff. not move. activated. Foot control is activ- ated.
  • Page 171 Instructions for use ESTETICA E70 Vision / E80 Vision 9 Eliminating disturbances Malfunction Cause Remedy ▶ Restart the software. Camera image freezes Electrical or electro- without the release magnetic interference button or foot control by other equipment. having been triggered.
  • Page 172 Instructions for use ESTETICA E70 Vision / E80 Vision 9 Eliminating disturbances Malfunction Cause Remedy ▶ Call a service technician. Status message: "Am- Malfunction in the am- ▶ Note the amalgam separator warning notice. algam separator" algam separator. Also refer to: Operating instructions of the amalgam separator ▶...
  • Page 173: 10Information Concerning The Electromagnetic Compatibility According To En Iec 60601-1-2

    Instructions for use ESTETICA E70 Vision / E80 Vision 10 Information concerning the electromagnetic compatibility according to EN IEC 60601-1-2 | 10.1 Electromagnetic Transmissions 10 Information concerning the electromagnetic compatibility according to EN IEC 60601-1-2 10.1 Electromagnetic Transmissions This product is designed for use in an environment like the one cited below. The customer or the user should ensure that the device is used in an environment of the specified type.
  • Page 174: Immunity To Electromagnetic Interference

    Instructions for use ESTETICA E70 Vision / E80 Vision 10 Information concerning the electromagnetic compatibility according to EN IEC 60601-1-2 | 10.3 Immunity to electromagnetic interference Interference im- IEC 60601 test levels Compliance level Electromagnetic en- munity tests vironment -...
  • Page 175 Instructions for use ESTETICA E70 Vision / E80 Vision 10 Information concerning the electromagnetic compatibility according to EN IEC 60601-1-2 | 10.3 Immunity to electromagnetic interference Interference im- IEC 60601 test Compliance level Electromagnetic environment munity tests levels - Guidelines...
  • Page 176: Recommended Safe Distances Between Portable And Mobile Hf Telecommunications Equipment And This Product

    Instructions for use ESTETICA E70 Vision / E80 Vision 10 Information concerning the electromagnetic compatibility according to EN IEC 60601-1-2 | 10.4 Recommended safe distances between portable and mobile HF telecommunications equipment and this product Within the frequency range of 150 kHz to 80 MHz, the field strength should be less than 1 V/m.