The system automatically sets all device numbers.
•
Populate drive bays based on the drive numbering sequence. Start from the drive bay with the lowest
device number.
•
All drives grouped into the same drive array must meet the following criteria:
◦
They must be either all SAS or all SATA.
◦
They must be either all hard drives or all solid-state drives.
◦
Drives should be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.
Installing a hot-plug drive in the front drive cage 1
CAUTION:
Do not operate the server with any of the front drive cage 1 bays empty. To maintain proper airflow and
sufficient cooling in the front drive cage 1, all drive bays in this cage should have a drive or a drive
blank.
Procedure
1. If installed, remove the security bezel.
2. Remove the drive blank:
•
LFF drive blank
•
SFF drive blank
3. Open the drive release lever:
•
LFF drive: Press the latch to open the release lever.
Installing a hot-plug drive in the front drive cage 1
61