Eight-Bay Sff Drive Cage Option; Installing The Optional Sff Hot-Plug Drive Cage - HP ProLiant ML350p Gen8 User Manual

Hide thumbs Also See for ProLiant ML350p Gen8:
Table of Contents

Advertisement

For rack models, if removed, install the security bezel (on page 21).
o

Eight-bay SFF drive cage option

Install the optional eight-bay SFF drive cage in drive cage bay 2 or drive cage bay 3.
To install an additional eight-bay SFF drive cage, an optional SAS controller is required. To obtain the option,
contact an HP authorized reseller.

Installing the optional SFF hot-plug drive cage

Do one of the following:
1.
For tower models, open and remove the bezel
o
For rack models, if installed, remove the security bezel (on page 21).
o
Power down the server (on page 20).
2.
Remove all power:
3.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
For tower models, do the following:
4.
Place the server on a flat, level surface with the access panel facing up.
a.
Remove the access panel (on page 23).
b.
For rack models, do the following:
5.
Extend the server from the rack (on page 24).
a.
Remove the access panel (on page 23).
b.
Release thumbscrews and remove the rack bezel.
c.
Remove the blank from box 2 or box 3.
6.
("Remove the tower
bezel" on page 21).
Hardware options installation 89

Advertisement

Table of Contents
loading

Table of Contents