Comtech EF Data CSAT-5060 Installation And Operation Manual page 89

C-band transceiver
Table of Contents

Advertisement

CSAT-5060 50 Watt C-Band Transceiver
Remote Control
Arguments
for
Command
Command
(Instruction
or
Parameter
Code and
Response
Type
qualifier)
to Query
Concise
N/A
18 bytes,
Alarm Status
numerical
Summary
N/A
1 byte,
Fault Status
alpha
numerical
Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Query only.
Used to Query the Alarm status of the CSAT
Example: CMS=abcdefghijklmnopqr'cr''lf'
where: a thru n = 0 or 1, 0 = OK 1 = FT
a = 24V Power Supply Alarm
b = 20V Power Supply Alarm
c = 12V Power Supply Alarm
d = 10V Power Supply Alarm
e = +5V Power Supply Alarm
f = -5V Power Supply Alarm
g = Tx Synthesizer Lock Detect Alarm
h = Tx IFLO Lock Detect Alarm
I = Rx Synthesizer Lock Detect Alarm
j = Rx IFLO Lock Detect Alarm
k = Reference Lock Detect Alarm
l = LNA Current Alarm
m = Fan Current Alarm
n = Temperature Alarm
o = HPA Thermal Shutdown Alarm
p = Internal IIC-bus Alarm
q = EEPROM checksum Alarm
r = NVRAM/RTC Low Battery Alarm
Query only.
Used to Query the status of the CSAT Summary
Fault Relay.
Example: SFS=0'cr''lf'
where: 0 = OK 1 = FT
Response to
Command
(Slave to Master)
N/A
N/A
A-17
MN/CSAT506050.IOM
Query
(Instruction
code and
Response to query
qualifier)
(Slave to Master)
CAS?
CAS=x....x (see description for
details of arguments)
SFS?
SFS=x (see description for details
of arguments)
Revision 0