Table 6- 14
Factory setting of the digital inputs
Digital input no.
Digital input 0 (DI0)
Digital input 1 (DI1)
Digital input 2 (DI2)
Digital input 3 (DI3)
Table 6- 15
Changing the digital input settings
Digital input no.
Digital input 0 (DI0)
Digital input 1 (DI1)
Digital input 2 (DI2)
Digital input 3 (DI3)
If you enable one of the digital inputs to be freely used for BICO technology (P701...P704 =
99), then you must interconnect this digital input to the required control command.
If value 99 is assigned to the digital input to define its function, this can only be reversed by
restoring the factory setting.
SINAMICS G110D
Operating Instructions, 2009-05-15, A5E02385577A AB
Control command
Switch motor on/off (ON/OFF1)
Reverse direction of rotation
Fault acknowledgment
Selects fixed frequency 1
Parameter
Description
P0003 = 2
Extended access to the parameters
P0701 = ...
Possible values for P0701 to P0704:
0: Digital input disabled
1: ON/OFF1
P0702 = ...
2: ON reverse /OFF1
3: OFF2 - coast to standstill
P0703 = ...
4: OFF3 - quick ramp-down
9: Fault acknowledge
P0704 = ...
10: JOG right
11: JOG left
12: Reverse
13: MOP up (increase frequency)
14: MOP down (decrease frequency)
15: Fixed frequency selector bit0
16: Fixed frequency selector bit1
17: Fixed frequency selector bit2
18: Fixed frequency selector bit3
22: QuickStop Source 1
23: QuickStop Source 2
24: QuickStop Override
25: DC brake enable
27: Enable PID
29: External trip
33: Disable additional freq setpoint
99: Enable BICO parameterization
Functions
6.3 Command sources
91