Functions
6.11 Operation in fieldbus systems
Table 6- 58
PKW error codes
Error code
Description
0
Illegal PNU (illegal parameter number; parameter number not available). PKW1=0,
PKW2=next PNU, PKW3=previous PNU.
1
Parameter value cannot be changed (because parameter is read-only)
2
Lower or upper limit violated (limit exceeded)
3
Erroneous sub-index. Note: not valid for task 4 "Getting parameter description". If
the parameter in the drive is not an array, the drive will reply with this error only if
the index is > 1. For index 0 or 1 the task will be executed. The response ID is then
4 or 5.
4
No array. Note: If the parameter in the drive is not an array, the drive will reply with
this error only if the index is > 1. For index = 0 or index = 1 the task will be executed.
The response ID is then = 4 or 5.
5
Parameter type is wrong/ incorrect data type.
6
Setting not allowed (parameter value can only be reset to zero).
7
Description cannot be changed; a PBEelement is not changeable and can only be
read.
8
PPO write, requested in the IR, not available.
9
Descriptive data not available.
10
Access group incorrect.
11
No parameter change rights. See parameter p0927. Must have status as master
control.
12
Password incorrect.
13
Text cannot be read in cyclic transmission.
14
Name cannot be read in cyclic transmission.
15
Text array is not available.
16
PPO write missing.
17
Drive operating state does not permit the set task at the moment.
18
Other error
19
Data cannot be read in cyclic transfer
20
Change request for a value which is between the lower an the upper limit, but there
are other reasons why the change request is not allowed; it is a parameter with
defined single values.
101
Parameter deactivated at the moment; parameter has no function in the present
state of the drive converter.
102
Reply does not fit into buffer; depends on the number of PKW and the maximum net
data length of the drive. Dependent on the number of PKW and the maximum net
data length in the drive.
104
Parameter value not permissible. The parameter value does not have an assigned
function in the drive converter or cannot be accepted at the instant of the change for
internal reasons (although it is within the limits) or the expert level has not been set
or the value is not within the selection list. [PKW1 = 104, PKW2 = next value]
105
Parameter is indexed
106
Request is not implemented/task not supported
109
PKW request access timeout or number of retries is exceeded or wait for response
from CPU side.
110
Parameter value cannot be changed (because parameter is Locked).
150
Operating Instructions, 2009-05-15, A5E02385577A AB
Errors set by task
1 to 15
2,3,7,8 or 11 to 14
2,3,7,8 or 11 to 14
4,6,7,8,11, or 12
6,7,8,11, or 12
2, 3, 7, 8 or 11 to 14
2, 3, 7, 8 or 11 to 14
5
(PROFIdrive 2.0 only)
15
(PROFIdrive 2.0 only)
2, 3, 7, 8 or 11 to 14
1 to 15
2, 3, 7, 8 or 11 to 14
5,10 or 15
SINAMICS G110D