6.10 Quick Stop function
The front edge of the load is detected by the sensor, which initiates the Quick Stop function.
Figure 6-17
The load is then slowed down and stopped.
Figure 6-18
There are two sensors on the conveyor section, so that the Quick Stop function can stop the
conveyor section in either direction when a load is detected.
How does it work?
The Quick Stop function is configured using BICO parameters and they are explained in the
table below.
Table 6- 51
Quick Stop parameters
Parameter
Description
P0881
Quick Stop function Input 1 is ON
P0882
Quick Stop function Input 2 is ON
P0883
Quick Stop override
132
Conveyor example 2
Conveyor example 3
Remarks
Allows Quick Stop source 1 command to be selected using
BICO. The signal is expected to be active low (default setting
P0886 = 2).
Allows Quick Stop source 2 command to be selected using
BICO. The signal is expected to be active low (default setting
(P0886 = 2).
Allows Quick Stop override command source to be selected
using BICO. The signal is expected to be active high.