Setup Instructions; Functions Setting Up - CDVI CD97-4ID User Manual

Cdv97 series, fisheye camera door station with proximity access control, 2 wire system
Table of Contents

Advertisement

SETUP INSTRUCTIONS

Function Programming
This section explains the settings of each
function, please refer to the table below:
To carry out programming of the function
required, the metal front panel must be
removed. Please refer to Fig 1.
Each operation is indicated by the LED
indicator and the buzzer on the unit,
Order
Setting items
1
Setting door station address
Setting door station
2
calling mode
3
Setting camera resolution
4
Setting the unlock mode
5
Setting the unlock time
Setting the nameplate
6
illumination mode
Setting night view LED
7
illumination mode
Setting ring back
8
9
Setting image display mode
Standard/Group calling mode
0 = Opened/1 = Closed
tone
Alternate switching mode
LED_NAME
Setting range
0~3
High/Low
01 to 99 seconds
On/Off/Auto
On/Off/Auto
Ring Once
Ring Continuous
No ring-back tone
Zoom mode
Full screen mode
LED_UNLOCK
LED_TALK
KEY_SET
KEY_4
KEY_3
KEY_2
RF CARD
KEY_1
Fig.1
Default value
0
Standard calling mode
High
0 = Opened
1 seconds
On
Auto
Ring Once
Alternate switching mode
-7-