Setup Instructions; Functions Setting Up - CDVI CDV97-1ID User Manual

Cdv97 series, fisheye door station with proximity access control, 2 wire system
Table of Contents

Advertisement

SETUP INSTRUCTIONS

Functions Setting Up

This section explains the settings of each
function. Please refer to the following table:
To perform the settings for the function
required, remove the metal front panel to
gain access to the 'Key Set' button.
Please refer to the diagram (right).
Each operation is indicated by the lighting
of the LED indicator on the unit and by the
sounding of the buzzer.
Order
Setting items
1
Setting door station address
Setting door station
2
calling mode
3
Setting camera resolution
4
Setting the unlock mode
5
Setting the unlock time
Setting the nameplate
6
illumination mode
Setting night view LED
7
illumination mode
8
Setting ring-back tone
9
Setting image display mode
LED_NAME
Setting range
0~3
Standard/Group calling mode
High/Low
0:opened/1:closed
01 to 99 seconds
On/Off/Auto
On/Off/Auto
Ringing one time
Ring continuously
No ring-back tone
Alternate switching mode
Zoom mode
Full screen mode
LED_UNLOCK
LED_TALK
KEY_SET
KEY_4
KEY_3
KEY_2
RF CARD
KEY_1
Default value
0
Standard calling mode
High
0:opened
1 seconds
On
Auto
Ringing one time
Alternate switching mode