Fisheye Camera D oor S tation W ith P roximity A ccess C ontrol USER MANUAL RF CARD RF CARD CD97-4ID CDV17-97A • Please read this manual carefully to ensure safe and correct operation. • Keep this manual well for future reference.
CONTENTS PARTS AND FUNCTIONS ..................3 Part Names......................3 Mounting ......................... 4 BASIC FUNCTIONS ....................6 Unlock Operations ....................6 Fisheye Camera ..................... 6 External Motion Detection ..................6 SETUP INSTRUCTIONS ..................7 Functions Setting Up ....................7 Setting Door Station Address ................. 8 Setting Door Station Calling Mode .................
PARTS AND FUNCTIONS Mounting The installation height is suggested to 145~160cm. Surface mounted The distance between the top of main unit and rain cover should ≥3mm Rain cover be not less than 3mm. Main unit Rain cover Main Unit AcDbMLeader (ACDB_MLEADER_CLASS) AcDbMLeader (ACDB_MLEADER_CLASS) 1.
Page 5
PARTS AND FUNCTIONS Terminal description Lock Control Jumper PIR Motion Detector Connect Port P L S + L 1 L 2 Main Connect Port Lock Control Jumper: To select the lock type. Motion Detector Connection Port: To connect external PIR motion detector. Main Connect Port: To connect the bus line and the electronic locks.
BASIC FUNCTIONS Unlock Operation Unlocking by Card/Tag When a registered user card/tag is presented to the ID card window, the UNLOCK indicator lights up, a single beep will be heard and the lock relay will activate. • If an unauthorised user card/tag is presented, three beeps will be heard and the lock relay will NOT activate.
SETUP INSTRUCTIONS Function Programming This section explains the settings of each function, please refer to the table below: To carry out programming of the function LED_UNLOCK required, the metal front panel must be LED_TALK removed. Please refer to Fig 1. KEY_SET KEY_4 Each operation is indicated by the LED...
PROGRAMMING INSTRUCTIONS Setting Door Station Address A total of 4 addresses can be configured. Addresses can be modified either before or after installation. 0 is default, to change the setting, please follow the steps: ID=0,1 door station ID=1,2 door station ID=2,3 door station ID=3,4...
Page 9
SETUP INSTRUCTIONS Each call button will respond to different addresses depending upon the calling mode set. Refer to the following for more information. 1.Standard calling mode (Address range 01-04 by default) Call button A: calls the monitor with address 01 by default. Call button B: calls the monitor with address 02 by default.
SETUP INSTRUCTIONS Setting Camera Resolution The resolution of the camera can be changed at any time between high or low resolution. High resolution is the default setting, to change the setting, please follow the steps below: In standby mode, press Press KEY_2 button to set the Press KEY_2 button again KEY_SET button twice.
SETUP INSTRUCTIONS Setting Unlock Time By default, the unlock time is 1 second, the time setting range is 1~99 seconds. To change the unlock time follow the steps below: Press and hold on KEY_2 In standby mode, press KEY_SET button three button.
SETUP INSTRUCTIONS Setting Night View LED Illumination Mode There are 3 working modes for the night view LED, Normally on, Normally off and Auto. Auto is the default setting, to change this setting, please follow the steps below: In standby mode, press Press KEY_4 button to set Press KEY_4 button again Press KEY_4 button again...
SETUP INSTRUCTIONS Setting Image Display Mode PLEASE NOTE: The following settings are only applicable for monitors that do not support manual screen operation for pan-tilt, i.e. CDV47M, CDV43 and CDV24 When the monitor is being called: When the door station calls a monitor, the camera image will be displayed on screen, there are 3 modes for the displayed image, Alternate switching mode, Zoom mode and Full screen mode.
SETUP INSTRUCTIONS Full screen mode: When answering the call, the image will be displayed on Zoom mode for 5 seconds then switching to Full screen as a reminder to enter talking status. 'Image Switching' Off Mode: the image switching reminder will not function in any image display mode.
Page 15
SETUP INSTRUCTIONS Authorising Master Add & Master Delete cards/tags: After powering on, within 10s, Press KEY_2 button. Show the first card to ID Show the second card to ID press and hold on KEY_SET card window, set the card card window, set the card of button for 3s.
Page 16
SETUP INSTRUCTIONS Adding User Cards: Show the MASTER CARD Show user cards to be Show the MASTER CARD ADD to ID card window in added in sequence. ADD again to exit. standby. UNLOCK Indicator:OFF UNLOCK Indicator:OFF UNLOCK Indicator:OFF TALK Indicator:ON TALK Indicator:Blink one time TALK Indicator:OFF Buzzer...
WIRING Connecting Electric Lock Door Lock Controlled with Internal Power 1 2 3 1.A fail secure (power on to unlock) should be used. Jumper position on 2&3 2.The door lock output is limited to 12V at a maximum of 250mA. PL S+ S- 3.Connect the jumper across on position 2 and 3 before connecting the lock.
1 2 3 4 5 6 • The door station is set to Standard mode in the example above. Refer to Page 9 for details. • The door station is compatible with all monitors within the CDVI 2Easy range. Connecting Multi Door Stations...
Basic IN-OUT Wiring in Standard Mode • The door station is compatible with all Code=1, DIP6=on monitors within the CDVI 2Easy range. (Slave 3) • Please set door station to group calling mode if there are more than 4 monitors on the system (Refer to Page 9) •...
Page 20
RF CARD ID=0 • The door station is compatible with all monitors within the CDVI 2Easy range. • The system can be extended by up to a maximum of 3 slave monitors for each monitor.(Connection via a CDV-DBC4A branch distribut o r is recommended)
APPENDIX Precautions • Clean the unit with soft cotton cloth, do not use the organic impregnate such as polishes or chemical clean agents. If necessary, use a little pure water or diluted soap and water to clean off dirt. • The unit is weather resistant. However do not use high pressure water cleaners on the door panel directly.
APPENDIX Cables and Requirments The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance which the system can reach. Basic IN-OUT Wiring Mode Cable and distance(unit:m) Cable Usage ≤2 IM ≤16 IM Twisted cable 2x0.75mm Twisted cable 2x1mm...
Page 23
APPENDIX Star Topology Wiring Mode With DBC4A1 DBC4A1 PC6A Cable and distance(unit:m) Cable Usage Twisted cable 2x0.75mm Twisted cable 2x1mm RF CARD -23-...
Page 24
DT-ENG-DT607-V1 The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.