WIRING

Connecting Basic One-to-one

Code=1, DIP6=on
L1
L2
DIP Switches
ON
DIP
1 2 3 4 5 6
• The door station is set to Standard mode in the example above. Refer to Page 9 for details.
• The door station is compatible with all monitors within the CDVI 2Easy range.

Connecting Multi Door Stations

To monitors
• A maximum of 4 door stations can be connected to the system.
• Please ensure to set the correct address for each door station, please refer to Page 8 for
more details regarding setting the addresses of door stations.
-18-
AC~
100~240VAC
PC6A
BUS(IM) BUS(DS)
1
door station
2
door station
st
nd
ID=0
ID=1
RF CARD
RF CARD
L1 L2 PL S+ S-
L1 L2 PL S+ S-
AC~
ID=0
L1 L2 PL S+ S-
3
door station
4
door station
rd
th
ID=2
ID=3
RF CARD
RF CARD
L1 L2 PL S+ S-
L1 L2 PL S+ S-
100~240VAC
A B C D
DBC4A1
PC6A
BUS(IM) BUS(DS)
Impedance
RF CARD
-
+
OFF
ON
switch