Pressure Regulator Unit Cobra - WAGNER Cobra 40-10 Operating Manual

High pressure double diaphragm pump
Table of Contents

Advertisement

EDITION 01/2012
OPERATING MANUAL
4.4.2

PRESSURE REGULATOR UNIT COBRA 40-10

1 Air pressure regulator
2 Ball valve
3 Pressure gauge
4 Compressed air connection
5 Filter pressure regulator AirCoat (Option)
The AirCoat regulator (5) must mounted in all mounting variants
of diaphragm pump in vertical position.
Positions of the ball valve:
1 Closed: Operating pressure in the air motor will be vented.
(Control pressure is available)
2 Closed: The air motor can still be under pressure.
3 Open: Working position.
4.4.3
PRESSURE REGULATOR UNIT COBRA 40-25
1
Pressure regulator
2
Ball valve
3
Pressure gauge
4
Compressed air connection
5
Safety valve
6
Filter pressure regulator
AirCoat (Option)
Positions of the ball valve
1
Open: Working position
2
Closed: The air motor can still be under pressure.
3
Closed: The operating pressure in the air motor is aired out by
pulling on the ring
(Control pressure (6) is available).
PART NUMBER DOC322851
3
3
2
1
2
4
2
1
2
3
B_01235
6
4
1
2
Cobra.
1
5
B_01208
3
5
B_02946
20