Basic Cleaning - WAGNER Cobra 40-10 Operating Manual

High pressure double diaphragm pump
Table of Contents

Advertisement

EDITION 01/2012
OPERATING MANUAL
5.2.2

BASIC CLEANING

1. Place empty container (5) under return
tube (4).
2. Place suction hose (7) in a container
with solvent (6).
3. Set pressure regulator (1) to approx.
0.05 MPa; 0.5 bar; 7.25 psi
4. Open return valve (3).
5. Slowly open ball valve (2).
6. Adjust the air pressure on the pressure
regulator (1) so that the pump runs
regularly.
7. Rinse the system until clean solvent
fl ows into the container (5).
8. Close ball valve (2).
9. Set return valve (3) to "spray" .
10. Point the gun, without nozzle, into
container (5) and open it.
11. Slowly open ball valve (2).
12. Rinse until clean solvent fl ows from
the gun.
13. Close ball valve (2).
14. When there is no pressure remaining
in the system close gun.
15. Secure gun.
16. Dispose of the contents of the
container (5) according to the local
regulations.
Note:
During cleaning procedure briefl y push the valve pushers (V).