Starting Up And Operation; Set Up And Connect; Set Up The Pump - WAGNER Cobra 40-10 Operating Manual

High pressure double diaphragm pump
Table of Contents

Advertisement

EDITION 01/2012
OPERATING MANUAL
5

STARTING UP AND OPERATION

5.1

SET UP AND CONNECT

5.1.1

SET UP THE PUMP

Note
This pump can be used as part of a spraying system for Airless or AirCoat applications.
The components can be found in the accessories list, provided that the system was not
obtained as a spraypack.
The nozzles must be selected according to the gun instructions.
Procedure:
1. Assemble the pump on a base frame a
trolley (6), or wall mounting.
2. For AirCoat systems:
Fit the additional fi lter pressure regulator (7)
(optional).
3. Attach high-pressure fi lter (3) (optional).
4. Fit suction system (5).
5. Attach return hose (4) (optional).
6. Connect high-pressure hose and gun (2) as
laid down in operating instructions.
Inclined surface!
Risk of accidents if the unit rolls away/falls
SIHI_0012_GB
PART NUMBER DOC322851
Position the carriage with the piston pump horizontally.
If the surface is inclined, position the feet of the carriage towards
the gradient.
Secure the carriage.
WARNING
Cobra.
22