Bleeding
Procedure
1. Place the pump on the head and unscrew threaded plug (5).
2. Slowly start up the pump and check the oil suction nipple until no more air-bubbles
withdraw.
3. The oil level A in the oil reservoir has to be within the specifi ed limit values.
4. Screw in threaded plug (5) and tighten with 3-4 Nm; 2.2-3 lbft.
5. Mount piston cover (1), cap with air-outlet and shuttering pressure stage.
6. The pump is ready for operation.
A
5
B_01224
36