WAGNER Cobra 40-10 Operating Manual page 14

High pressure double diaphragm pump
Table of Contents

Advertisement

EDITION 01/2012
OPERATING MANUAL
Description
Ø air inlet connection (female)
Min. Ø compressed air hose
Air consumption at 0.6 MPa; 6 bar; 87
psi per DS
Sound pressure level at maxi.
permissible air pressure *
Sound pressure level at 0.45 MPa; 4.5
bar; 65.27 psi air pressure *
Sound pressure level at 0.3 MPa; 3 bar;
43.5 psi air pressure *
Diameter piston of air motor
Diameter material inlet connection
(male)
Diameter material outlet connection
(female)
Weight
pH range of the material
Maxi. material pressure at pump inlet
Material temperature
Ambient temperature
Allowable sloping position at work
Filling amount hydraulic oil
* A rated sound pressure level measured at 1 m distance according to DIN EN 14462: 2005.
Reference measurements have been made by SUVA (Swiss accident insurance institute).
Outgoing air containing oil!
Risk of poisoning if inhaled
SIHI_0023_GB
PART NUMBER DOC322851
Units
Zoll
inch
mm
inch
NL
dB(A)
dB(A)
dB(A)
mm
Inch
mm
Zoll
Inch
kg
lb
pH
MPa
bar
psi
°C
°F
°C
°F
L
Cu inch
Provide water-free and oil-free compressed air (quality standard
5.5.4 as per ISO 8573.1) 5.5.4 = 40 μm / +7 / 5 mg/m³.
Cobra 40-10
G 1/2
13
0.51
3.5
74
72
69
80
3.15
M36x2
G 3/8
19
41.9
3.5-9
2
20
290
+10 ÷ +80
+50 ÷ +176
+10 ÷ +60
+50 ÷ +140
±10
0.065
3.97
WARNING
Cobra.
Cobra 40-25
G 1/2
19
0.75
8.3
76
74
71
100
4
M36x2
G 1/2
33
72.8
3.5-9
2
20
290
+10 ÷ +80
+50 ÷ +176
+10 ÷ +60
+50 ÷ +140
±10
0.120
7.32
14