OPERATING MANUAL
2.2.4

CLEANING

De-energize the unit electrically.
Disconnect the pneumatic supply line.
Relieve the pressure from the unit.
Ensure that the flash point of the cleaning agent is at least 5 K above the ambient
temperature.
To clean, use only solvent-free cloths and brushes. Never use hard objects or spray on
cleaning agents with a gun.
An explosive gas/air mixture forms in closed containers.
When cleaning units with solvents, never spray into a closed container.
Earth the container.
2.2.5

HANDLING HAZARDOUS LIQUIDS, VARNISHES AND PAINTS

When preparing or working with paint and when cleaning the unit, follow the working
instructions of the manufacturer of the paints, solvents and cleaning agents being
used.
Take the specified protective measures, in particular wear safety goggles, protective
clothing and gloves, as well as hand protection cream if necessary.
Use a mask or breathing apparatus if necessary.
For sufficient health and environmental safety: Operate the unit in a spray booth or on
a spraying wall with the ventilation (extraction) switched on.
Wear suitable protective clothing when working with hot materials.
2.2.6

TOUCHING HOT SURFACES

➞ Touch hot surfaces only if you are wearing protective gloves.
➞ When operating the unit with a coating material with a temperature of > 43 °C; 109.4 °F:
- Identify the unit with a warning label that says „Warning - hot surface".
Order No.
9998910 Information label
9998911 Safety label
2.3

CORRECT USE