5.1.2

EARTHING

Discharge of electrostatically charged components in atmospheres
containing solvents!
Explosion hazard from electrostatic sparks
SIHI_0041_GB
Heavy paint mist if earthing is insufficient!
Risk of poisoning
Insufficient paint application quality
SIHI_0003_GB
Earthing scheme (example)
Pump
Floor conductive
PART NUMBER DOC322851
WARNING
Clean the piston pump only with a damp cloth.
WARNING
Earth all unit components.
Earth the workpieces being painted.
Paint container
Conveyor
Object
Spraying stand
Cobra.