5.3.3

SHUTTING DOWN AND CLEANING

Note The device should be cleaned for maintenance purposes, etc. Ensure that no
remaining material dries and sticks.
Procedure:
1. Working break -> carry out Paragraph 5.3.2.
2. Basic cleaning -> carry out Paragraph 5.2.2.
3. Maintain the gun as laid down in the operating instructions.
4. Clean and check the suction system and, in particular, the suction fi lter.
5. When using a high-pressure fi lter:
Clean and check the fi lter insert and fi lter body.
6. Clean the outside of the system.
Brittle filter pressure regulator!
The container on the filter pressure regulator becomes brittle
through contact with solvents and can burst
Flying parts can cause injury
SIHI_0014_GB
7. Put the whole system back together.
8. Fill the system with solvent as laid down in Paragraph 4.2.3 "Filling with working
material" .
Gas mixtures can explode if there is an incompletely filled
pump!
Danger to life from flying parts
SIHI_0025_GB
5.4

LONG-TERM STORAGE

When storing the device for longer periods of time it is necessary to thoroughly clean it
and protect it from corrosion. Replace the water or solvent in the material pump with a
suitable preserving oil.
Procedure:
1. Carry out Paragraph 5.3.3 "Shutting down and cleaning" , points 1 through 7.
2. Cleaning with preserving agent according to paragraph 5.2.2.
3. Protect the air motor with pneumatic oil:
Connect an oiler to the compressed air inlet and run for a few double strokes.
PART NUMBER DOC322851
Do not clean the container on the pressure regulator with
solvent.
Ensure that the pump and suction system are always completely
filled with cleaning agent or working medium.
Do not spray the unit empty after cleaning.