How To Access Diagnostic Information - Baldor 23H Series Installation & Operating Manual

Ac servo control
Hide thumbs Also See for 23H Series:
Table of Contents

Advertisement

Section 1
General Information

How to Access Diagnostic Information

Action
Apply Power
Display mode showing motor
speed.
Press DISP key 6 times
Scroll to Diagnostic Information
screen
Press ENTER key
Access diagnostic information.
Press DISP key
Display showing control
temperature.
Press DISP key
Display showing bus voltage.
Press DISP key
Display showing % overload
current remaining.
Press DISP key
Display showing real time opto
input & output states.
(0=Open, 1=Closed).
Press DISP key
Display showing actual drive
running time.
Press DISP key
Display showing operating zone,
voltage and control type.
Press DISP key
Display showing continuous
amps; PK amps rating; amps/volt
scale of feedback, power base ID.
Press DISP key
Display showing which Group1 or
2 expansion boards are installed
and recognized.
Press DISP key
Display showing software version
and revision installed in the
control.
Press DISP key
Displays exit choice.
5-2 Troubleshooting
Description
Display
Logo display for 5 seconds.
No faults present. Local keypad
mode. If in remote/serial mode,
disable drive then press local for
this display.
Diagnostic Access screen.
First Diagnostic Information
screen.
XXXV
Opto Inputs states (Left);
Opto Outputs states (Right).
HR.MIN.SEC format.
ID is a hexadecimal value.
In this case, no expansion boards
are installed.
Press ENTER to exit diagnostic
information.
Comments
MN723

Advertisement

Table of Contents
loading

Table of Contents