Size F Single Phase Power Installation
Figure 3-15 Size F Single Phase 230/460VAC Power Connections
Note 1
* Circuit
Breaker
Note 3
B1
*Optional
Note 4
Line
Reactor
B2
Note 3
L1
Control
3-16 Receiving & Installation
(See Figure 3-15.)
Figure 3-14 Jumper Configuration
Place JP2 on the High Voltage Circuit Board across pins 1 and 2.
L1
L2
Earth
Note 2
C1
* Optional components not provided with control.
Notes:
C2
1.
2.
L2
L3
3.
Baldor
4.
JP2
Pins 1 & 2 = Single Phase
Pins 2 & 3 = Three Phase
L1
L2
* Fuse
Connection
B1
C1
See "Protective Devices" described previously in this section.
Use same gauge wire for Earth ground as is used for L1, L2 and L3.
Metal conduit should be used. Connect conduits so the use of a
Reactor or RC Device does not interrupt EMI/RFI shielding.
See Line/Load Reactors described previously in this section.
See Recommended Tightening Torques in Section 7.
1
Note 1
MN723