Rga Assemblies - Baldor 23H Series Installation & Operating Manual

Ac servo control
Hide thumbs Also See for 23H Series:
Table of Contents

Advertisement

Section 1
General Information
Dynamic Braking (DB) Hardware Continued

RGA Assemblies

Input
HP
Minimum
Volts
Ohms
230
1 - 2
3 - 5
7.5 - 10
15 - 20
25 - 40
50
460
1 - 3
120
5 - 7.5
10
15 - 25
30 - 60
75 - 250
300 - 450
A-4 Appendix
RGA Assemblies include braking resistors completely assembled and mounted in a
NEMA 1 enclosure. A listing of available RGA assemblies is provided in Table A-2. The
minimum resistance "Minimum Ohms" shown in the table is the minimum resistor value
that can be connected to the control without causing damage to the internal dynamic
brake transistor for E, ER and MR controls.
RGA assemblies can also be used with EO and MO controls in combination with an RTA
assembly when more than 4000 watts of brake capacity is needed. In this case, the
minimum resistance of the RGA assembly must be equal to or greater than the minimum
resistance specified for the RTA assembly. Refer to Section 3 "Optional Dynamic Brake
Hardware" for wiring diagram.
Table A-2 Dynamic Braking Resistor Assemblies (RGA)
600
1200
30
RGA630
RGA1230
20
RGA620
RGA1220
10
RGA1210
6
RGA1206
4
RGA1204
2
RGA6120
RGA12120
60
RGA660
RGA1260
30
RGA630
RGA1230
20
RGA620
RGA1220
10
RGA1210
4
RGA1204
2
Continuous Rated Watts
2400
4800
RGA2430
RGA2420
RGA4820
RGA2410
RGA4810
RGA2406
RGA4806
RGA2404
RGA4804
RGA2402
RGA4802
RGA6402
RGA24120
RGA2460
RGA4860
RGA2430
RGA4830
RGA2420
RGA4820
RGA2410
RGA4810
RGA2404
RGA4804
RGA6404
RGA2402
RGA4802
RGA6402
6400
9600
RGA9602
RGA14202
RGA9604
RGA14204
RGA9602
RGA14202
14200
MN723

Advertisement

Table of Contents
loading

Table of Contents