Baldor 23H Series Installation & Operating Manual page 36

Ac servo control
Hide thumbs Also See for 23H Series:
Table of Contents

Advertisement

J1
1
2
3
4
5
JP2
(on main control board)
Refer to Table 3-8
for jumper placement information.
JP1
(on main control board)
Resolver Feedback Module
Jumper
JP1
JP2
MN723
Figure 3-29 Analog Inputs Equivalent Circuits
30KW
-15VDC
20KW
+
1.96KW
+15VDC
10KW
JP1
+
4-20mA
500W
10KW
X N/C
Figure 3-30 Control Board Jumper Locations
1 2 3
Table 3-8 Control Board Jumper
Jumper Position
1-2
Voltage Speed Command Signal. (Factory Setting)
2-3
4-20mA Speed Command input at Analog #2
1-2
Factory Setting
2-3
Not used.
.033 mF
Notes:
5KW
To Microprocessor
10KW
To Microprocessor
10KW
See recommended terminal tightening torques in Section 7.
JP1
See recommended terminal tightening torques in Section 7.
Description of Jumper Position Setting
+
All OP Amps are TL082 or TL084
Analog Ground is separated from
Chassis Ground. Electrically they
are separated by an RC network.
(on bottom side of resolver
feedback module)
1–2
Internal Index
2–3
External Index
Receiving & Installation 3-25