Section 1
General Information
Program Mode Continued

Initialize New Software

Action
Apply Power
Press PROG key
Press Y or B key
Press ENTER key
Press Y or B key
Press ENTER key
Press Y key
Press ENTER key
Press Y key
Press ENTER key
Press Y key
Press ENTER key
Press Y key
Press ENTER key
Press DISP key
Press DISP key
4-8 Programming & Operation
When new software is installed, the control must be initialized to the new software version
and memory locations. Use the following procedure to initialize the software.
Note: All parameter values are changed when the control is reset to factory settings.
Note: After factory settings have been restored, the drive must again be tuned.
Description
Keypad Display shows this
opening message.
If no faults and programmed for
LOCAL operation.
Enter program mode.
Scroll to Level 2 Blocks.
Select Level 2 Blocks.
Scroll to the Miscellaneous block.
Select Miscellaneous block.
Scroll to Factory Settings
parameter.
Access Factory Settings
parameter.
Scroll to YES, to choose original
factory settings.
Restores factory settings.
Scroll to menu exit.
Return to display mode.
Scroll to diagnostic info block.
Access diagnostic information.
Display mode showing software
version and revision installed in
the control.
Displays exit choice.
Display
Logo display for 5 seconds.
Display mode. Stop LED on.
V
represents blinking cursor.
"Loading Presets" is first message
"Operation Done" is next
"No" is displayed last.
Display mode. Stop LED on.
Displays commanded speed,
direction of rotation, Local/
Remote and motor speed.
Verify new software version.
XXX-X.XX
Press ENTER to exit diagnostic
information.
Comments