Analog Outputs; Digital Inputs; Digital Outputs; Diagnostic Indications - Baldor 23H Series Installation & Operating Manual

Ac servo control
Hide thumbs Also See for 23H Series:
Table of Contents

Advertisement

Section 1
General Information
Other Analog Input:
Full Scale Range
Resolution

Analog Outputs:

Analog Outputs
Full Scale Range
Source Current
Resolution

Digital Inputs:

Opto-isolated Logic Inputs
Rated Voltage
Input Impedance
Leakage Current

Digital Outputs:

Opto-isolated Logic Outputs
ON Current Sink
ON Voltage Drop
Maximum Voltage

Diagnostic Indications:

No Faults
Current Sense Fault
Ground Fault
Line Power Loss
Microprocessor Reset
Coprocessor Fault
Over temperature (Motor or Control)
Over speed
Note: All specifications are subject to change without notice.
MN723
0 - 10 VDC (0 to –10VDC and 0 to +10VDC are valid inputs)
9 bits + sign
2 Assignable
0 - 5 VDC
1 mA maximum
8 bits
9 Assignable
10 - 30 VDC (closed contacts std)
6.8 k Ohms
10 mA maximum
4 Assignable
60 mA Max
2 VDC Max
30 VDC
No EXB Installed
Overload - 1 minute
Overload - 3 seconds
Overcurrent FLT
DC Bus High
DC Bus Low
Lost User Data
Low INIT Bus V
Memory Error
Logic Supply Fault
Invalid Base ID
Inverter Base ID
New Base ID
PWR Base FLT
Regen R PWR FLT
Line Regen FLT
User FLT Text
Specifications, Ratings & Dimensions 7-3