Section 1
General Information
Block Title
OUTPUT LIMITS
OPERATING ZONE
MIN OUTPUT SPEED
MAX OUTPUT SPEED
PK CURRENT LIMIT
PWM FREQUENCY
CUR RATE LIMIT
CUSTOM UNITS
MAX DECIMAL PLACES
VALUE AT SPEED
VALUE DEC PLACES
VALUE SPEED REF
UNITS OF MEASURE
UNITS OF MEASURE 2
PROTECTION
OVERLOAD
EXTERNAL TRIP
LOCAL ENABLE INP
FOLLOWING ERROR
MISCELLANEOUS
RESTART AUTO/MAN
RESTART FAULT/HR
RESTART DELAY
FACTORY SETTINGS
HOMING SPEED
HOMING OFFSET
SECURITY
SECURITY STATE
CONTROL
ACCESS TIMEOUT
ACCESS CODE
MOTOR DATA
MOTOR RATED AMPS
MOTOR POLES
RESOLVER SPEEDS
CALC PRESETS
B-4 Appendix
Table B-2 Parameter Block Values Level 2
Level 2 Blocks
Parameter
P#
2001
2002
2003
2004
2005
2006
2101
2102
2103
2104
2105
2106
2201
2202
2203
2204
2301
2302
2303
2304
2305
2306
2401
2402
2403
2501
2502
2503
2204
Adjustable Range
1–STD CONST TQ
2–STD VAR TQ
3–QUIET CONST TQ
4–QUIET VAR TQ
0-2500
0-22500 RPM (4 Pole Motor)
0-14.0
1.0-5.0 KHZ (Standard)
1.0-16.0 KHZ (Quiet)
0-10.000 SEC
0-5
1-65535/1-65535
0-5 (Serial Only)
1 to 65535 (Serial Only)
See Table 4-3.
See Table 4-3. (Serial Only)
0–FAULT, 1–FOLDBACK
0–OFF, 1–ON
0–OFF, 1–ON
0–OFF, 1–ON
0–MANUAL, 1–AUTOMATIC
0-10
0-120 SECONDS
0–NO, 1–YES
0-MAX Speed
0-65535 CNTS
0–OFF
1–LOCAL SECURITY
2–SERIAL SECURITY
3–TOTAL SECURITY
0-600 SEC
0-9999
0-999.9
0–100
0 - 10
0–NO, 1–YES
Factory
User
Setting
QUIET
CONST TQ
0 RPM
2500
CALC
8.0 KHZ
0.004 SEC
5
1./
01000
0
00000/
01000
-
-
FOLDBACK
OFF
OFF
OFF
MANUAL
0
0 SEC
NO
100 RPM
1024
OFF
0 SEC
9999
CALC
4
1
NO
MN723