Program Mode Continued

Changing Parameter Values when Security Code Not Used

Action
Apply Power
Press PROG key
Press Y or B key
Press ENTER key
Press ENTER key
Press Y key
Press ENTER
Press Y key
Press ENTER key
Press DISP key
4-6 Programming & Operation
Use the following procedure to program or change a parameter already programmed into
the control when a security code is not being used.
The example shown changes the operating mode from Keypad to Bipolar.
Description
Keypad Display shows this
opening message.
If no faults and programmed for
LOCAL operation.
Access programming mode.
Scroll to Level 1 Input Block.
Access Input Block.
Access Operating Mode
parameter.
Scroll to change selection.
Save selection to memory.
Scroll to menu exit.
Return to Input Block.
Return to Display Mode.
Display
Logo display for 5 seconds.
Display mode. Stop LED on.
Press ENTER to access INPUT
block parameter.
Keypad mode shown is the
factory setting.
Keypad mode shown is the
factory setting.
At flashing cursor, select desired
mode, BIPOLAR in this case.
Press ENTER to save selection.
Typical display mode.