Initialize New Software Eeproms - Baldor 29M Installation And Operating Manual

Servo control
Table of Contents

Advertisement

Program Mode Continued

Initialize New Software EEPROMs

Action
Apply Power
Press PROG key
Press Y or
key
Press ENTER key
Press Y or
key
Press ENTER key
Press Y key
Press ENTER key
Press Y key
Press ENTER key
Press Y key
Press ENTER key
Press Y key
Press ENTER key
Press DISP key
Press DISP key
4-8 Programming & Operation
After new EEPROMs are installed, the control must be initialized to the new software
version and memory locations. Use the following procedure to Initialize the EEPROMs.
Description
Keypad Display shows this
opening message.
If no faults and programmed for
LOCAL operation.
Enter program mode.
Scroll to Level 2 Blocks.
Select Level 2 Blocks.
Scroll to the Miscellaneous block.
Select Miscellaneous block.
Scroll to Factory Settings
parameter.
Access Factory Settings
parameter.
Scroll to YES, to choose original
factory settings.
Restores factory settings.
Scroll to menu exit.
Return to display mode.
Scroll to diagnostic info block.
Access diagnostic information.
Display mode showing software
version and revision installed in
the control.
Displays exit choice.
Display
Logo display for 5 seconds.
Display mode. Stop LED on.
V
represents blinking cursor.
"Loading Presets" is first message
"Operation Done" is next
"No" is displayed last.
Display mode. Stop LED on.
Displays commanded speed,
direction of rotation, Local/
Remote and motor speed.
Verify new software version.
XXX-X.XX
Press ENTER to exit diagnostic
information.