4.5 SBK function 
In  automatic  mode,  press  [
executing;  press  [
program block by block. 
Caution: 
① In G28‐G30, single block also can be stopped at the center point; 
② The stop points of single block in fixed circle are ①, ②, ⑥ in the figure below; when the single blocks of ①, ② stops, 
the feeding pauses and the pause indicator is on. 
4.6 BDT function 
In automatic mode, press [
the line after '/' in the program invalid. 
4.7 Stopping automatic operating 
Two methods are available to stop automatic operating, i.e. enter stop command where the program will 
stop (M00, M01) and press the
Program stops 
After executing the block with M00 or M01, the automatic operating stops, which is same to single block 
stop, and all mode information is saved. Start with CNC and the automatic operation can be started again. 
 
BZ001M056A  ADT‐DK300A/400A  Engraving  Machine 
]  to  start  the  SBK  function.  Current  program  block  stops  after 
]  again  and  next  block  stops  after  executing.  The  SBK  mode  allows  checking  the 
] to start the BDT function, which will make the block instructions in 
  key on the operation panel to stop the machine tool. 
 