106 
 
Spindle air blow output port 
 
 
Range     
 
 
Unit     
 
 
Authority 
 
 
Default 
 
 
Effective time 
 
 
Note 
11. Hardware interface definition and 
11.1. Installation layout 
11.1.1. External interface diagram 
 
(1) X axis, Y axis, Z axis, A axis: 
15‐core D‐pin socket connects to step motor drive or digital AC servo drive 
(5) XS5 digital input: 
 
BZ001M056A  ADT‐DK300A/400A  Engraving  Machine 
Instant 
Configure spindle elastic cutter detection port, and control elastic cutter 
signal via external switch signal. 
 
None 
Operation admin or higher 
========= 
Instant 
Used for spindle air blow output port configuration; the default value is 
null. 
connection instructions 
XS12 spindle encoder 
XS9 serial port 
XS11 CSR communication 
Network 
XS8 spindle 
XS7 handheld box 
XS1 X‐axis 
XS2 Y‐axis 
XS6 digital output 
XS3 Z‐axis 
XS5 digital input 
XS4 A‐axis