11.1.3. Installation precautions 
Installation condition for electric cabinet 
(1) The cabinet must be able to effectively prevent dust, coolant and organic solution entering; 
(2)  When  design  electric  cabinet,  the  distance  between  rear  cover  and  case  should  be  at  least  20CM; 
considering the temperature rises in the cabinet, the temperature difference between interior and exterior of 
the cabinet shouldn't exceed 10℃; 
(3) The cabinet should be installed with fan to ensure interior ventilation; 
(4) The display panel should be installed at the position can't be sprayed by the coolant; 
(5)  When  design  electric  cabinet,  the  external  electrical  interference  should  be  reduced  to  lowest  to 
prevent interfering with the system; 
To prevent interference 
The  system  is  designed  with  anti‐interference  measures  such  as  shielding  space  electromagnetic 
radiation,  absorbing  impact  current  and  filtering  power  clutter,  which  can  prevent  interference  with  the 
system in certain degree. To ensure system stability, please take the following measures to install and connect 
the system: 
 
BZ001M056A  ADT‐DK300A/400A  Engraving  Machine 
 