11.1.3. Installation precautions
Installation condition for electric cabinet
(1) The cabinet must be able to effectively prevent dust, coolant and organic solution entering;
(2) When design electric cabinet, the distance between rear cover and case should be at least 20CM;
considering the temperature rises in the cabinet, the temperature difference between interior and exterior of
the cabinet shouldn't exceed 10℃;
(3) The cabinet should be installed with fan to ensure interior ventilation;
(4) The display panel should be installed at the position can't be sprayed by the coolant;
(5) When design electric cabinet, the external electrical interference should be reduced to lowest to
prevent interfering with the system;
To prevent interference
The system is designed with anti‐interference measures such as shielding space electromagnetic
radiation, absorbing impact current and filtering power clutter, which can prevent interference with the
system in certain degree. To ensure system stability, please take the following measures to install and connect
the system: