084
HOME Check for alarm
085
HOME Check Enable
Range
Unit
Authority
Default
Effective time
Note
087
Default process plane
Range
Unit
Authority
Default
Effective time
Note
089
IP address
090
Subnet mask
091
Default gateway
Range
Unit
Authority
Default
Effective time
Note
99
BZ001M056A ADT‐DK300A/400A Engraving Machine
acceleration/deceleration, and this parameter is valid in preprocessing
mode.
:
0~1
:
None
:
Operation admin or higher
:
0, 1
:
Instant
:
Used to set whether prompt user to reset under certain conditions,
ensuring that the user has performed the operation;
If the value is set to 0, it won't check, and will run directly.
:
G17,18,19
:
None
:
Operation admin or higher
:
G18 (L series)/G17 (M series)
:
Instant
:
Set the default processing plane to XY or XZ; modify the default plane, so
that it isn't need to specify the modal plane value while programming,
and write plane related instructions directly in stead;
:
0~255
:
None
:
Operation admin or higher
:
192.168.0.123
255.255.255.0
192.168.0.1
:
Restart
:
Used to configure Ethernet parameters, which shall comply with the
actual network settings, or else it can't be accessed normally.
After configured successfully, the user can perform the ping command