Mounting instruction Genius
10.3.2 Protocol
The protocol of the RS-232 interface is described in a separate document. It is not neces­
sary for the operation and initial start up.
10.4

IO-Control

The IO-Control logically assigns the digital inputs and outputs to the status of the
assignments are free programmable.
The IO-control controls signals from different sources in the
outside to the
G
.
ENIUS
ponding outputs. Each input signal (source name) and each output signal (destination
name) is identified by its name. The link in the menu
names. The link is either the direct signal or its inverted value (NOT) and is stored in a
register. An overview of all names is shown on the figure IO control.
10.4.1 Fixed level
10.4.1.1
Input signal
Low
The output is always inactive if this is
Open
The output is not influence by the IO-
control. The output can be change for
Example:
The G
 shall stay always in Auto mode. (in the menu Auto/Manual any changes shall be blocked).
ENIUS
The relay output 1 of the CPU­CARD shall be controlled by the RS­ 232 (the IO­control shall not be allowed  
to change this) 
Ausgang
Set Auto
Set Manual
CPU I/O K1
10.4.2 HV ON/OFF control
The HV ON/OFF control is responsible for the switch ON/OFF of the magnet current power
supply, the filament power supply (filament) and the high voltage as well as the control of
the emission of the emission current.
If the filament is switched ON always the magnet current will be switched ON. If the high
voltage is switched ON always the magnet current and the filament will be switched ON.
The high voltage and the filament can only be switched ON if the
control
are enabled. The emission will be enabled if the high voltage is switched ON and
the
pocket rotation control
10.4.2.1
Input signal
Version 2.0.6
According to the configuration these signals are linked to the corres­
Input
Function
set to
Low
example by the RS-232 or by an
internal function.
status is that the pocket is in its position.
Input
Function
G
ENIUS
I/O Logic
Function if
The output is always active if
this is set to
Logik
= NOT
=
=
Function if
58/78
G
ENIUS
and signals applied from
(I/O Setting) is based on this
„NOT"
is set
NOT Low
No defined function!
Input
Low
Low
Open
safety control
and
„NOT"
is set
Ferrotec GmbH
. The
error