Spare And Wearing Parts; Shutdown Procedures - ferrotec genius Mounting Instructions

Evaporation controller
Table of Contents

Advertisement

Mounting instruction Genius
1. The machine may only be operated by trained and authorized personnel.
2. The different responsibilities in the operation of the machine must be clearly defined
and observed so that no confusion with respect to responsibilities arises, thus endan­
gering safety.
3. Whenever any work (operation, maintenance, repair, etc.) is carried out, the shut­
down procedure specified in this Mounting instruction must be followed.
4. The operating personnel may not apply any working methods that impair the safety
of the machine.
5. The operating personnel are co-responsible for ensuring that no unauthorized person
works with or on the machine.
6. The operating personnel must immediately report any changes in the machine that
impair its safety to the responsible executive.
4.3

Spare and wearing parts

Spare parts and accessories that have not been supplied by us have also not been tested
and approved by us. The fitting and/or use of such products could therefore negatively
affect the design characteristics of your machine. Ferrotec GmbH accepts no liability for
damages arising from the use of non-original parts and non-original accessories.
D A N G E R !
repairs within the unit.
Danger: high voltage!
4.4

Shutdown Procedures

N O T I C E !
personnel according to the definition in DIN EN 60 204.
D A N G E R !
without fail before carrying out any cleaning, repair or maintenance work
1.
Switch off the unit:
2.
Switch off the high voltage unit with the HV-off button at
3.
Turn off the On/Off switch located in the back of the
4.
Turn off the On/Off mains device switch at the front of the high voltage power supply.
Switch off the main circuit breaker at the back of the high voltage power supply
5.
Pull out the mains plugs at the controll device
6.
FPS X201 and the high voltage power supply HVP X301.
7.
Wait for at least 3 minutes before starting work on the electrical equipment. The capa-
citors must discharge themselves
For maintenance and repair ensure that nothing is still electrically live. Use an earthing rod
to earth all the high-voltage feedthroughs. Close the door of the electrical cabinet during
cleaning to ensure no dust or water can enter into the cabinet.
Version 2.0.6
Fundamentally speaking, it is forbidden to make any
The shut down procedure may only be initiated by skilled
The following procedure for switching off is to be followed
18/78
hand remote.
G
ENIUS
(X101).
G
ENIUS
X101, the filament power supply
G
ENIUS
Ferrotec GmbH