Root Dti Server In Free-Run Mode - Symmetricom TimeCreator 1000 User Manual

Docsis timing interface server
Hide thumbs Also See for TimeCreator 1000:
Table of Contents

Advertisement

Table 5-4. TimeCreator 1000 Input Signal Source
Reference Source
Real-Time Clock
(RTC)
USER
Use the following procedure to provision the TimeCreator 1000 mode of operation
as either a root DTI server or subtending server.
Note: A TimeCreator 1000 that is provisioned as a subtending server
must use the reference source of a root DTI server.

Root DTI Server in Free-run Mode

The TimeCreator 1000 operates in free-run mode when there is no qualified
external reference and the TOD is either set by the user, set with NTP, or set to the
default Real Time Clock (RTC) mode.
User Time Set Mode
The Set Clock Date Time command is used to set the system time.
Example
To provision the TimeCreator 1000 as a root server in free-run mode with the TOD
set by the user to the current time, perform the following steps:
1. Login at the Admin or Power-User level (see Login, on page 74).
2. Type
set tod-source user
3. Type
set clock date <date> time <time>
NTP (Client) Set Mode
The Set TOD-Source NTP command is used to provision the Time of Day source to
be an NTP server.
097-93100-01 Revision C – February, 2010
Server Mode
Root
Clock on IMC used to acquire the TOD. Frequency is
provided by IOC's clock in freerun mode
Root
User manually enters TOD. Frequency is provided by IOC's
clock in freerun mode
and press Enter.
Chapter 5 Provisioning
Setting the DTI Server Type
Description
and press Enter.
TimeCreator 1000 User's Guide