Chapter 4 General Guidelines for using the Symmetricom TimeCreator 1000
CLI commands
Saving The Present Configuration To Non-volatile Memory
Enter the following command to backup the current configuration:
Set configuration backup
Enter the following command to backup the current IOC configuration in the IMC
card:
Set configuration backup IOC
Enter the following command to backup the current IMC configuration in the IOC1
card:
Set configuration backup IMC IOC1
Enter the following command to backup the current IMC configuration in the IOC2
card:
Set configuration backup IMC IOC2
Note: IMC configuration changes are not saved automatically, so it is
necessary use the command "set configuration backup" to explicitly
save the changes. Failure to save changes with this command will
result in IMC configuration changes being lost after the IMC reboots.
See
Backing up Provisioning
Restoring Default Configuration
To restore factory defaults, while preserving users and IP configuration:
Set configuration default
To restore factory defaults:
Set configuration factory
See
Restoring Provisioning
Determining Status
Enter the following commands to display current alarms, the unit status, GPS
information, and inventory:
Show alarms (presently active alarms)
66
TimeCreator 1000 User's Guide
Data, on page 110 for additional details.
Data, on page 111 for additional details.
097-93100-01 Revision C – February, 2010